High pressure liquid chromatographic analysis of the serum concentration of cefuroxime after an intravenous bolus injection of cefuroxime in patients with a coronary artery bypass grafting.
M J Koot, F N IJdenberg, R M Stuurman, J Poell, L J Bras, J J Langemeijer, L Lie-A-Huen
{"title":"High pressure liquid chromatographic analysis of the serum concentration of cefuroxime after an intravenous bolus injection of cefuroxime in patients with a coronary artery bypass grafting.","authors":"M J Koot, F N IJdenberg, R M Stuurman, J Poell, L J Bras, J J Langemeijer, L Lie-A-Huen","doi":"10.1007/BF01970173","DOIUrl":null,"url":null,"abstract":"<p><p>A simple reversed-phase high pressure liquid chromatographic method was developed for the determination of cefuroxime in the serum of patients undergoing coronary artery bypass grafting. The serum was cleaned up with a 3.3% solution of perchloric acid in water. Cefalexine was used as an internal standard. Detection was made by a UV multi-wavelength detector. The optimum wavelength for cefuroxime is 275 nm. The absolute recovery of this method was 90.9%; the limit of quantification was 0.7 mg/l. This analytical method was used in a study to investigate the cefuroxime serum concentration--time curves in 26 patients undergoing coronary artery bypass grafting. It was found that one single dose is sufficient to obtain effective serum concentrations.</p>","PeriodicalId":19804,"journal":{"name":"Pharmaceutisch weekblad. Scientific edition","volume":"14 6","pages":"360-4"},"PeriodicalIF":0.0000,"publicationDate":"1992-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF01970173","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutisch weekblad. Scientific edition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/BF01970173","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11
Abstract
A simple reversed-phase high pressure liquid chromatographic method was developed for the determination of cefuroxime in the serum of patients undergoing coronary artery bypass grafting. The serum was cleaned up with a 3.3% solution of perchloric acid in water. Cefalexine was used as an internal standard. Detection was made by a UV multi-wavelength detector. The optimum wavelength for cefuroxime is 275 nm. The absolute recovery of this method was 90.9%; the limit of quantification was 0.7 mg/l. This analytical method was used in a study to investigate the cefuroxime serum concentration--time curves in 26 patients undergoing coronary artery bypass grafting. It was found that one single dose is sufficient to obtain effective serum concentrations.