Association of Elevated Oxidized Low Density Lipoprotein to Low Density Lipoprotein Ratio (Ox LDL/LDL) with Sub Clinical Atherosclerosis in Patients Receiving Maintenance Haemodialysis

Sadia Rehman, S Kumar, K. Nisar, Zara Sami, F. Mehboob, Suniya Rehman
{"title":"Association of Elevated Oxidized Low Density Lipoprotein to Low Density Lipoprotein Ratio (Ox LDL/LDL) with Sub Clinical Atherosclerosis in Patients Receiving Maintenance Haemodialysis","authors":"Sadia Rehman, S Kumar, K. Nisar, Zara Sami, F. Mehboob, Suniya Rehman","doi":"10.46663/ajsmu.v8i1.30-35","DOIUrl":null,"url":null,"abstract":"Objective: To assess the oxidized low density lipoprotein (ox-LDL) to low density lipoprotein (LDL) ratio as an indicator of subclinical atherosclerosis in haemodialysis patients Methodology: This case control study was carried out at Jinnah Post Graduate Medical Center Karachi, from January to December 2018. The haemodialysis patients were selected from the dialysis center (group B) whereas the controls were recruited from normal healthy population (group A). To access the status of atherosclerosis, doppler ultrasonography technique was employed to detect the intima media thickness (IMT) ratio of common carotid artery of study subjects as well as controls. Lipid peroxidation was detected by serum oxidized LDL (ox-LDL) levels. Results: The mean of carotid artery intima thickness in group A was 0.43±0.02, the mean intima thickness of group B samples was 1.0±0.09. The mean ratio of Ox-LDL/LDL in group A was 0.003±0.001. While in group B the mean of Ox-LDL: LDL was 0.012±0.002. Ox-LDL was found to have a positive linear relationship with mean carotid artery intima media thickness ratio (r=0.8) in haemodialysis group. Conclusion: Ox-LDL to LDL ratio is much enhanced in patients on maintenance haemodialysis showing increased lipid peroxidation. Ox-LDL has a positive linear relationship with mean carotid artery intima media thickness ratio which is a marker of sub clinical atherosclerosis. Early detection of elevated Ox-LDL will help nephrologists in early detection and treatment of sub clinical atherosclerosis.","PeriodicalId":350655,"journal":{"name":"ANNALS of JINNAH SINDH MEDICAL UNIVERSITY","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ANNALS of JINNAH SINDH MEDICAL UNIVERSITY","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46663/ajsmu.v8i1.30-35","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To assess the oxidized low density lipoprotein (ox-LDL) to low density lipoprotein (LDL) ratio as an indicator of subclinical atherosclerosis in haemodialysis patients Methodology: This case control study was carried out at Jinnah Post Graduate Medical Center Karachi, from January to December 2018. The haemodialysis patients were selected from the dialysis center (group B) whereas the controls were recruited from normal healthy population (group A). To access the status of atherosclerosis, doppler ultrasonography technique was employed to detect the intima media thickness (IMT) ratio of common carotid artery of study subjects as well as controls. Lipid peroxidation was detected by serum oxidized LDL (ox-LDL) levels. Results: The mean of carotid artery intima thickness in group A was 0.43±0.02, the mean intima thickness of group B samples was 1.0±0.09. The mean ratio of Ox-LDL/LDL in group A was 0.003±0.001. While in group B the mean of Ox-LDL: LDL was 0.012±0.002. Ox-LDL was found to have a positive linear relationship with mean carotid artery intima media thickness ratio (r=0.8) in haemodialysis group. Conclusion: Ox-LDL to LDL ratio is much enhanced in patients on maintenance haemodialysis showing increased lipid peroxidation. Ox-LDL has a positive linear relationship with mean carotid artery intima media thickness ratio which is a marker of sub clinical atherosclerosis. Early detection of elevated Ox-LDL will help nephrologists in early detection and treatment of sub clinical atherosclerosis.
维持血液透析患者氧化低密度脂蛋白/低密度脂蛋白比值(Ox LDL/LDL)升高与亚临床动脉粥样硬化的关系
目的:探讨氧化低密度脂蛋白(ox-LDL)与低密度脂蛋白(LDL)比值作为血液透析患者亚临床动脉粥样硬化的指标。方法:2018年1月至12月在卡拉奇真纳研究生医学中心进行病例对照研究。血液透析患者选自透析中心(B组),对照组选自正常健康人群(A组)。采用多普勒超声技术检测研究对象和对照组颈总动脉内膜中膜厚度(IMT)比,了解动脉粥样硬化状况。通过血清氧化LDL (ox-LDL)水平检测脂质过氧化。结果:A组颈动脉内膜厚度平均值为0.43±0.02,B组颈动脉内膜厚度平均值为1.0±0.09。A组Ox-LDL/LDL平均比值为0.003±0.001。B组Ox-LDL: LDL均值为0.012±0.002。血液透析组Ox-LDL与平均颈动脉内膜中膜厚度比呈线性正相关(r=0.8)。结论:维持血液透析患者的Ox-LDL / LDL比值明显升高,表现为脂质过氧化增加。Ox-LDL与平均颈动脉内膜中膜厚度比呈线性正相关,是亚临床动脉粥样硬化的标志。早期发现Ox-LDL升高有助于肾病学家早期发现和治疗亚临床动脉粥样硬化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信