COMPARATIVE ASSESSMENT OF OPERATING CONDITIONS OF TUBULAR DROP MANHOLES OF SEWERAGE SYSTEMS

A. Kravchuk, O. Kravchuk
{"title":"COMPARATIVE ASSESSMENT OF OPERATING CONDITIONS OF TUBULAR DROP MANHOLES OF SEWERAGE SYSTEMS","authors":"A. Kravchuk, O. Kravchuk","doi":"10.33744/0365-8171-2022-111-085-091","DOIUrl":null,"url":null,"abstract":"The evaluation of standard pipes of drop sewerage manholes is carried out on the basis of the literature data analysis. A new design of the drop manhole with height-variable cross-sectional area is proposed on this basis. A series of experimental studies was conducted on a specially mounted setup to study and compare the characteristics and operating conditions of standard structures and structures of the proposed design. The models of drop standpipes were made of plexiglass, which allowed to visualize the structure of fluid flows in both cases. It is established that three modes of motion can take place in drop standpipes, depending on the passed flow rate: pressureless, transitional and pressure. Pressureless mode of motion should be considered as calculated for permanent cross-sectional drop. Much attention has been paid to measuring the magnitude of dynamic loads from the falling flow to the manhole bottom in the research. Non-uniformity coefficient of the dynamic load from the flow stream impact also was determined. It was defined that its value depends on the flow rate passed by the standpipe and can reach values of 3 or more for drops, that are made of a constant cross-sectional standpipe. The non-uniformity coefficient of the dynamic load for such drop should be taken equal to 1.5. The non-uniformity coefficient does not exceed 1.5 for arbitrary flow rates for variable cross-sectional standpipes.","PeriodicalId":440945,"journal":{"name":"Automobile Roads and Road Construction","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Automobile Roads and Road Construction","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33744/0365-8171-2022-111-085-091","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The evaluation of standard pipes of drop sewerage manholes is carried out on the basis of the literature data analysis. A new design of the drop manhole with height-variable cross-sectional area is proposed on this basis. A series of experimental studies was conducted on a specially mounted setup to study and compare the characteristics and operating conditions of standard structures and structures of the proposed design. The models of drop standpipes were made of plexiglass, which allowed to visualize the structure of fluid flows in both cases. It is established that three modes of motion can take place in drop standpipes, depending on the passed flow rate: pressureless, transitional and pressure. Pressureless mode of motion should be considered as calculated for permanent cross-sectional drop. Much attention has been paid to measuring the magnitude of dynamic loads from the falling flow to the manhole bottom in the research. Non-uniformity coefficient of the dynamic load from the flow stream impact also was determined. It was defined that its value depends on the flow rate passed by the standpipe and can reach values of 3 or more for drops, that are made of a constant cross-sectional standpipe. The non-uniformity coefficient of the dynamic load for such drop should be taken equal to 1.5. The non-uniformity coefficient does not exceed 1.5 for arbitrary flow rates for variable cross-sectional standpipes.
污水系统管状落孔运行工况的比较评价
在文献资料分析的基础上,对滴落污水井口标准管进行了评价。在此基础上,提出了一种变高度截面积的落孔设计新方案。在一个专门安装的装置上进行了一系列的实验研究,研究和比较了标准结构和设计结构的特性和工作条件。滴水立管的模型是由有机玻璃制成的,这使得在两种情况下流体流动的结构可视化。根据通过流量的不同,液滴立管可以发生三种运动模式:无压、过渡和有压。应考虑无压运动模式,以计算永久横截面下降。在研究中,对井底降流动载荷的大小进行了测量。确定了流冲击下动载荷的非均匀性系数。定义了其值取决于立管通过的流量,对于由恒定截面立管组成的液滴,其值可以达到3或更多。这种跌落的动荷载不均匀系数取等于1.5。对于变截面立管,任意流量的非均匀性系数不超过1.5。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信