{"title":"Research on the effect of the size of the wall-hanging air-conditioner indoor unit on the indoor thermal comfort","authors":"Kuanbing Caozhu, Changfa Ji","doi":"10.21203/rs.3.rs-27036/v1","DOIUrl":null,"url":null,"abstract":"\n The geometrical dimension of the wall-hanging air-conditioner indoor unit affects the indoor thermal comfort. In this paper, fluent software is used and standard k-e two equation turbulent model is chosen to carry out the simulation of the indoor temperature field and flow field of six different sizes of the single wall-hanging indoor air-conditioner in the room. The temperature distribution, velocity distribution and PMV distribution of the plane which is 1.8 m from the ground are given. It can be known that under the condition of six kinds of sizes of the wall-hanging air-conditioner indoor unit, when the size of the air-conditioner indoor unit is 0.4m × 0.2m × 0.2 m, the temperature variation at the z = 1.8 m section is relatively small, the temperature distribution is more uniform. When the size of the air-conditioner indoor unit is 0.5m × 0.2m × 0.2 m, the temperature difference at the z = 1.8 m section is relatively smaller, PMV is closest to 0, and the thermal sensation is almost moderate. Therefore when the size of the air-conditioner indoor unit is 0.5m × 0.2m × 0.2 m, better indoor comfort can be achieved.","PeriodicalId":262953,"journal":{"name":"Journal of Chemistry: Education Research and Practice","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chemistry: Education Research and Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21203/rs.3.rs-27036/v1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The geometrical dimension of the wall-hanging air-conditioner indoor unit affects the indoor thermal comfort. In this paper, fluent software is used and standard k-e two equation turbulent model is chosen to carry out the simulation of the indoor temperature field and flow field of six different sizes of the single wall-hanging indoor air-conditioner in the room. The temperature distribution, velocity distribution and PMV distribution of the plane which is 1.8 m from the ground are given. It can be known that under the condition of six kinds of sizes of the wall-hanging air-conditioner indoor unit, when the size of the air-conditioner indoor unit is 0.4m × 0.2m × 0.2 m, the temperature variation at the z = 1.8 m section is relatively small, the temperature distribution is more uniform. When the size of the air-conditioner indoor unit is 0.5m × 0.2m × 0.2 m, the temperature difference at the z = 1.8 m section is relatively smaller, PMV is closest to 0, and the thermal sensation is almost moderate. Therefore when the size of the air-conditioner indoor unit is 0.5m × 0.2m × 0.2 m, better indoor comfort can be achieved.