Evaluation of the Influence of a New Design of Orthosis on the Loads Applied On the Knee Joint

Kamali M. J Ann Bioeng
{"title":"Evaluation of the Influence of a New Design of Orthosis on the Loads Applied On the Knee Joint","authors":"Kamali M. J Ann Bioeng","doi":"10.33513/bioe/1901-01","DOIUrl":null,"url":null,"abstract":"Background: Knee osteoarthritis influences the ability of the subjects during standing and walking. Although knee offloading orthosis reduces the loads applied on the knee joint and decrease knee pain, most of the subjects discontinue brace use due to stretching the ligaments structure of the knee joints, and tendency of the brace to migrate distally. Therefore, a new type of orthosis was developed to overcome the aforementioned problem. The aim of this research was to check the influence of this orthosis on reducing the loads applied on the knee joint. Method: A group of normal subjects was recruited in this study to walk with and without the orthosis. A Kistler force plate and Qualisys motion analysis system were used to collect the kinetic and kinematic parameters. The difference between walking parameters under two conditions was evaluated by paired t test. The p-value of difference was set at 0.05. Results: There was no difference between spatiotemporal gait parameters during walking with and without the orthosis (P-value>0.05). The adductor moment applied on the knee joint was 0.433±0.138 and 0.478±0.143 N.m/BW while walking with and without the orthosis, respectively (P-value=0.006). There was a slight increase in the hip adductor moment while walking with orthosis. Conclusion: The new design of the orthosis reduces the loads applied on the knee joint through the hip joint. The new orthosis decreases the loads applied on the knee joint without any negative influences on the walking performance.","PeriodicalId":243433,"journal":{"name":"Journal of Annals of Bioengineering","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Annals of Bioengineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33513/bioe/1901-01","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Knee osteoarthritis influences the ability of the subjects during standing and walking. Although knee offloading orthosis reduces the loads applied on the knee joint and decrease knee pain, most of the subjects discontinue brace use due to stretching the ligaments structure of the knee joints, and tendency of the brace to migrate distally. Therefore, a new type of orthosis was developed to overcome the aforementioned problem. The aim of this research was to check the influence of this orthosis on reducing the loads applied on the knee joint. Method: A group of normal subjects was recruited in this study to walk with and without the orthosis. A Kistler force plate and Qualisys motion analysis system were used to collect the kinetic and kinematic parameters. The difference between walking parameters under two conditions was evaluated by paired t test. The p-value of difference was set at 0.05. Results: There was no difference between spatiotemporal gait parameters during walking with and without the orthosis (P-value>0.05). The adductor moment applied on the knee joint was 0.433±0.138 and 0.478±0.143 N.m/BW while walking with and without the orthosis, respectively (P-value=0.006). There was a slight increase in the hip adductor moment while walking with orthosis. Conclusion: The new design of the orthosis reduces the loads applied on the knee joint through the hip joint. The new orthosis decreases the loads applied on the knee joint without any negative influences on the walking performance.
一种新型矫形器对膝关节负荷影响的评价
背景:膝关节骨性关节炎影响受试者站立和行走的能力。虽然膝关节减压矫形术减少了施加在膝关节上的负荷,减轻了膝关节疼痛,但由于拉伸膝关节的韧带结构,以及支架向远端移动的倾向,大多数受试者停止使用支架。因此,开发了一种新型矫形器来克服上述问题。本研究的目的是检查这种矫形器对减轻膝关节负荷的影响。方法:本研究招募一组正常受试者,分别使用矫形器行走和不使用矫形器行走。利用Kistler测力板和Qualisys运动分析系统采集了运动和运动学参数。两种情况下行走参数的差异采用配对t检验。差异p值设为0.05。结果:带矫形器与不带矫形器行走时的时空步态参数差异无统计学意义(p值>0.05)。行走时膝关节内收肌力矩分别为0.433±0.138、0.478±0.143 N.m/BW (p值=0.006)。使用矫形器行走时,髋内收力矩略有增加。结论:新设计的矫形器通过髋关节减轻了膝关节的负荷。新的矫形器减少了施加在膝关节上的负荷,而对行走性能没有任何负面影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信