Control method for a three-port interface converter using an indirect matrix converter with an active snubber circuit

K. Kato, J. Itoh
{"title":"Control method for a three-port interface converter using an indirect matrix converter with an active snubber circuit","authors":"K. Kato, J. Itoh","doi":"10.1109/EPEPEMC.2008.4635328","DOIUrl":null,"url":null,"abstract":"This paper proposes a novel control method for an interface converter using an indirect matrix converter with three power supplies, which consist of two AC and one DC supplies. An active snubber circuit in the indirect matrix converter is used as an interface with the DC power supply. The proposed control method is based on the indirect control method with a triangular carrier wave [10]. Therefore the proposed method can be easily applied to a DC/DC converter. In addition, this paper proposes reducing the number of switching during one carrier period for the inverter stage converter. In the proposed method, the inverter stage carrier is controlled asymmetry to reduce the switching times in the inverter stage. To apply the proposed method, the switching loss of the inverter stage can be decreased to 2/3 times in comparison with a conventional method. The validity of the proposed method is confirmed by simulation and experimental results.","PeriodicalId":149421,"journal":{"name":"2008 13th International Power Electronics and Motion Control Conference","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 13th International Power Electronics and Motion Control Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPEPEMC.2008.4635328","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

Abstract

This paper proposes a novel control method for an interface converter using an indirect matrix converter with three power supplies, which consist of two AC and one DC supplies. An active snubber circuit in the indirect matrix converter is used as an interface with the DC power supply. The proposed control method is based on the indirect control method with a triangular carrier wave [10]. Therefore the proposed method can be easily applied to a DC/DC converter. In addition, this paper proposes reducing the number of switching during one carrier period for the inverter stage converter. In the proposed method, the inverter stage carrier is controlled asymmetry to reduce the switching times in the inverter stage. To apply the proposed method, the switching loss of the inverter stage can be decreased to 2/3 times in comparison with a conventional method. The validity of the proposed method is confirmed by simulation and experimental results.
采用带有源缓冲电路的间接矩阵变换器的三端口接口变换器的控制方法
本文提出了一种基于间接矩阵变换器的接口变换器的控制方法,该变换器由两个交流电源和一个直流电源组成。间接矩阵变换器采用有源缓冲电路作为与直流电源的接口。所提出的控制方法是基于三角形载波[10]的间接控制方法。因此,该方法可以很容易地应用于DC/DC变换器。此外,本文还提出了减少逆变级变换器在一个载波周期内的开关次数。该方法通过控制逆变级载波的不对称性,减少了逆变级的开关次数。与传统方法相比,采用该方法可将逆变级的开关损耗降低到2/3。仿真和实验结果验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信