Assessment of Different Properties of Lightweight Concrete using Expanded Polystyrene Beads Extracted from Thermocol Wastage

Tek Raj Gyawali
{"title":"Assessment of Different Properties of Lightweight Concrete using Expanded Polystyrene Beads Extracted from Thermocol Wastage","authors":"Tek Raj Gyawali","doi":"10.3126/hijase.v3i2.52294","DOIUrl":null,"url":null,"abstract":"Nepal is facing the problem of thermocol wastage, especially in the damping site nearby the urban areas. The thermocol wastage were crushed by a hammer and the extracted expanded polystyrene (EPS) beads was used as aggregates to produce the lightweight concrete. The content of EPS beads was 0, 20, 30, 40, 50, and 60 % by the total volume. Mechanical properties like density, different strengths, and Young’s modulus were experimentally evaluated on ranging percentages of EPS. The 28-day compressive, flexural, splitting tensile strengths and Young’s modulus of the control mixture were 59.9 MPa, 5.21 MPa, 4.43 MPa, and 20898 MPa respectively. The decrease on compressive strength was by 62 %, 72 %, 81 %, 88 %, and 93 % respectively for 20 %, 30 %, 40 %, 50 %, and 60 % EPS content respectively. It was 26 %, 41 %, 51 %, 57 %, and 69 % for flexural strength, 46 %, 60 %, 70 %, 80 %, and 88 % for the splitting tensile strength and 45 %, 56 %, 61 %, 70 %, and 77 % for Young’s modulus respectively. Drying shrinkage, freezing and thawing, and water absorption tests were conducted to evaluate the durability of EPS concrete. All properties were compared with the auto-cleaved lightweight concrete (ALC). It revealed that the EPS beads extracted from the thermocol wastage can be re-used to produce the structural and non-structural concrete depending on its percentages. It can easily solve the never-decomposing problems of thermocol wastage. Moreover, ALC can be replaced by EPS concrete for the in-fill and partition walls of the buildings.","PeriodicalId":122917,"journal":{"name":"Himalayan Journal of Applied Science and Engineering","volume":"29 1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Himalayan Journal of Applied Science and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3126/hijase.v3i2.52294","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Nepal is facing the problem of thermocol wastage, especially in the damping site nearby the urban areas. The thermocol wastage were crushed by a hammer and the extracted expanded polystyrene (EPS) beads was used as aggregates to produce the lightweight concrete. The content of EPS beads was 0, 20, 30, 40, 50, and 60 % by the total volume. Mechanical properties like density, different strengths, and Young’s modulus were experimentally evaluated on ranging percentages of EPS. The 28-day compressive, flexural, splitting tensile strengths and Young’s modulus of the control mixture were 59.9 MPa, 5.21 MPa, 4.43 MPa, and 20898 MPa respectively. The decrease on compressive strength was by 62 %, 72 %, 81 %, 88 %, and 93 % respectively for 20 %, 30 %, 40 %, 50 %, and 60 % EPS content respectively. It was 26 %, 41 %, 51 %, 57 %, and 69 % for flexural strength, 46 %, 60 %, 70 %, 80 %, and 88 % for the splitting tensile strength and 45 %, 56 %, 61 %, 70 %, and 77 % for Young’s modulus respectively. Drying shrinkage, freezing and thawing, and water absorption tests were conducted to evaluate the durability of EPS concrete. All properties were compared with the auto-cleaved lightweight concrete (ALC). It revealed that the EPS beads extracted from the thermocol wastage can be re-used to produce the structural and non-structural concrete depending on its percentages. It can easily solve the never-decomposing problems of thermocol wastage. Moreover, ALC can be replaced by EPS concrete for the in-fill and partition walls of the buildings.
利用热废液中提取的膨胀聚苯乙烯微珠评价轻量化混凝土的不同性能
尼泊尔正面临着热能浪费的问题,特别是在城市地区附近的阻尼场地。用锤击法粉碎热废液,提取出膨胀聚苯乙烯(EPS)微珠作为集料,制备轻质混凝土。EPS微球的含量分别为0、20、30、40、50、60%。力学性能,如密度,不同的强度,杨氏模量,实验评估了不同百分比的EPS。对照混合物的28天抗压、抗折、劈裂抗拉强度和杨氏模量分别为59.9 MPa、5.21 MPa、4.43 MPa和20898 MPa。EPS含量分别为20%、30%、40%、50%和60%时,抗压强度分别降低62%、72%、81%、88%和93%。抗弯强度分别为26%、41%、51%、57%和69%,劈裂抗拉强度分别为46%、60%、70%、80%和88%,杨氏模量分别为45%、56%、61%、70%和77%。通过干缩、冻融和吸水试验对EPS混凝土的耐久性进行了评价。所有性能均与自动劈裂轻量混凝土(ALC)进行了比较。结果表明,从热水废水中提取的EPS珠可以根据其百分比重新用于生产结构和非结构混凝土。它可以很容易地解决永远不分解的问题,热浪费。此外,在建筑的填充墙和隔墙中,可以用EPS混凝土代替ALC。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信