A high luminosity position sensitive neutron detector for residual stress measurements

M. Moon, Changhee Lee, V. Em, H. Kang, U. Nam, A. Gabriel
{"title":"A high luminosity position sensitive neutron detector for residual stress measurements","authors":"M. Moon, Changhee Lee, V. Em, H. Kang, U. Nam, A. Gabriel","doi":"10.1109/NSSMIC.2001.1008463","DOIUrl":null,"url":null,"abstract":"Because the diffraction angle is equal or close to 90/spl deg/ in residual stress measurements by neutron diffraction, the luminosity of the device can be increased by expansion of the detection window height without deformation of the diffraction peak. A high luminosity position sensitive neutron detector has been designed and fabricated for measuring residual stress. The detector has a working window of 200 /spl times/ 100 mm/sup 2/. The detector has high efficiency, good position resolution and linearity, small position error and low background counts. The results of the detector characteristics are presented.","PeriodicalId":159123,"journal":{"name":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2001.1008463","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

Because the diffraction angle is equal or close to 90/spl deg/ in residual stress measurements by neutron diffraction, the luminosity of the device can be increased by expansion of the detection window height without deformation of the diffraction peak. A high luminosity position sensitive neutron detector has been designed and fabricated for measuring residual stress. The detector has a working window of 200 /spl times/ 100 mm/sup 2/. The detector has high efficiency, good position resolution and linearity, small position error and low background counts. The results of the detector characteristics are presented.
用于残余应力测量的高光度位置灵敏中子探测器
由于在中子衍射残余应力测量中衍射角等于或接近90/spl°/,因此可以在不改变衍射峰的情况下通过扩大检测窗口高度来增加器件的光度。设计并制作了一种用于测量残余应力的高光度位置灵敏中子探测器。该探测器的工作窗口为200 /spl倍/ 100 mm/sup 2/。该检测器效率高,位置分辨率和线性度好,位置误差小,背景计数少。给出了探测器特性的计算结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信