Power quality improvement with shunt active filter under various mains voltage using Teaching Learning Based optimization

Soumya Mishra, P. K. Ray
{"title":"Power quality improvement with shunt active filter under various mains voltage using Teaching Learning Based optimization","authors":"Soumya Mishra, P. K. Ray","doi":"10.1109/RAECS.2015.7453308","DOIUrl":null,"url":null,"abstract":"In this paper, instantaneous reactive power theory based a modified control algorithm is implemented for 3-phase 3-wire shunt active power filter to suppress harmonics and reactive power under non ideal source voltage. The reference current signals are generated by sensing the source voltage, load current and dc bus voltage. With these signals the gate driving pulses are generated via hysteresis band current controller. To check robustness of the control algorithm four different cases such as unbalanced, balanced distorted, unbalanced distorted main voltage and faults on load are considered. For more improvement in the performance of active filter, the Active filter is optimized with Teaching-Learning-Based optimization. The simulation work is carried out in MATLAB/SIMULINK Power system block set. The performance of the implemented algorithm with Teaching-Learning-Based optimization is found quite effective and satisfactory under these conditions.","PeriodicalId":256314,"journal":{"name":"2015 2nd International Conference on Recent Advances in Engineering & Computational Sciences (RAECS)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 2nd International Conference on Recent Advances in Engineering & Computational Sciences (RAECS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RAECS.2015.7453308","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this paper, instantaneous reactive power theory based a modified control algorithm is implemented for 3-phase 3-wire shunt active power filter to suppress harmonics and reactive power under non ideal source voltage. The reference current signals are generated by sensing the source voltage, load current and dc bus voltage. With these signals the gate driving pulses are generated via hysteresis band current controller. To check robustness of the control algorithm four different cases such as unbalanced, balanced distorted, unbalanced distorted main voltage and faults on load are considered. For more improvement in the performance of active filter, the Active filter is optimized with Teaching-Learning-Based optimization. The simulation work is carried out in MATLAB/SIMULINK Power system block set. The performance of the implemented algorithm with Teaching-Learning-Based optimization is found quite effective and satisfactory under these conditions.
采用基于教与学的优化方法改善不同市电电压下并联有源滤波器的电能质量
本文提出了一种基于改进控制算法的瞬时无功理论,实现了三相三线并联有源滤波器在非理想电压下的谐波和无功抑制。参考电流信号是通过感应源电压、负载电流和直流母线电压产生的。利用这些信号通过磁滞带电流控制器产生栅极驱动脉冲。为了验证控制算法的鲁棒性,考虑了主电压不平衡、平衡畸变、不平衡畸变和负载故障四种情况。为了进一步提高有源滤波器的性能,对有源滤波器进行了基于教学的优化。仿真工作在MATLAB/SIMULINK Power系统模块集中进行。在这些条件下,采用基于教学的优化方法实现的算法的性能是非常有效和令人满意的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信