PC Based Blood Pressure Meter for E-health Application

B. Mustapha, M. Hassan, Z. Mohamad, I. Kamaruddin, R. Yahya
{"title":"PC Based Blood Pressure Meter for E-health Application","authors":"B. Mustapha, M. Hassan, Z. Mohamad, I. Kamaruddin, R. Yahya","doi":"10.1109/ICAIET.2014.59","DOIUrl":null,"url":null,"abstract":"A blood pressure is one of the fundamental vital signs, and its measurement is important to medical professionals and the general public alike. Nowadays, there are several types of blood pressure meter available manufactured from various companies. In order to meet the demand on telemedicine and technology advancement, a new form of blood pressure meter is desirable. This prototype of blood pressure meter is interfaced with a personal computer (PC) which able to simulate the measurement process in real time. The proposed system is divided by two parts which are hardware and software. Hardware section includes pressure sensor, microcontroller, bulb, cuff and conditioning circuits. The systems operate on oscillometric principle which gives the results in terms of systolic, diastolic and MAP (Mean Arterial Pressure). Furthermore, these results will be presented and simulated on the software. MP Lab software packages is used to program the microcontroller. The user interface was developed by using Visual Basic 6.0 language, which highlights the user friendly attributes. Moreover, the simulated waveform will evaluate the blood pressure and gives the blood pressure value. This application shows significant improvement on the overall performance and gives reliable results. The average percentage difference for the systolic and diastolic blood pressure between the OMRON BP meter and proposed e-BPMS are ± 0.95% and ± 1.32% respectively, which is very small and still in the acceptable range. The framework used to design proposed machine is easy to understand, and it can be extended further to endorse and meet requirements of e-health applications.","PeriodicalId":225159,"journal":{"name":"2014 4th International Conference on Artificial Intelligence with Applications in Engineering and Technology","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 4th International Conference on Artificial Intelligence with Applications in Engineering and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAIET.2014.59","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A blood pressure is one of the fundamental vital signs, and its measurement is important to medical professionals and the general public alike. Nowadays, there are several types of blood pressure meter available manufactured from various companies. In order to meet the demand on telemedicine and technology advancement, a new form of blood pressure meter is desirable. This prototype of blood pressure meter is interfaced with a personal computer (PC) which able to simulate the measurement process in real time. The proposed system is divided by two parts which are hardware and software. Hardware section includes pressure sensor, microcontroller, bulb, cuff and conditioning circuits. The systems operate on oscillometric principle which gives the results in terms of systolic, diastolic and MAP (Mean Arterial Pressure). Furthermore, these results will be presented and simulated on the software. MP Lab software packages is used to program the microcontroller. The user interface was developed by using Visual Basic 6.0 language, which highlights the user friendly attributes. Moreover, the simulated waveform will evaluate the blood pressure and gives the blood pressure value. This application shows significant improvement on the overall performance and gives reliable results. The average percentage difference for the systolic and diastolic blood pressure between the OMRON BP meter and proposed e-BPMS are ± 0.95% and ± 1.32% respectively, which is very small and still in the acceptable range. The framework used to design proposed machine is easy to understand, and it can be extended further to endorse and meet requirements of e-health applications.
基于PC的血压计在电子医疗中的应用
血压是基本的生命体征之一,它的测量对医学专业人员和普通公众都很重要。如今,有几种类型的血压计可由不同的公司制造。为了满足远程医疗的需求和技术的进步,一种新型的血压计势在必行。该血压计样机与一台能够实时模拟测量过程的个人计算机(PC)相连。该系统分为硬件和软件两部分。硬件部分包括压力传感器、微控制器、灯泡、袖带和调理电路。该系统运行在振荡原理,给出结果的收缩压,舒张压和MAP(平均动脉压)。此外,这些结果将在软件上进行展示和模拟。使用mplab软件包对微控制器进行编程。用户界面采用Visual Basic 6.0语言开发,突出了用户友好的特点。此外,模拟的波形将评估血压并给出血压值。这个应用程序在整体性能上有了显著的改进,并提供了可靠的结果。欧姆龙血压计与e-BPMS的收缩压和舒张压的平均百分比差异分别为±0.95%和±1.32%,差异很小,仍在可接受范围内。所提出的机器设计框架易于理解,并且可以进一步扩展以支持和满足电子卫生应用的需求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信