System modeling and signal processing of microwave Doppler radar for cardiopulmonary sensing

M. Singh, Akhilesh Gupta, Salony Permanand, U. Singh, O. P. Singh, Yong Hoon Kim, Ashish Kumar Singh
{"title":"System modeling and signal processing of microwave Doppler radar for cardiopulmonary sensing","authors":"M. Singh, Akhilesh Gupta, Salony Permanand, U. Singh, O. P. Singh, Yong Hoon Kim, Ashish Kumar Singh","doi":"10.1109/ICSPCOM.2015.7150652","DOIUrl":null,"url":null,"abstract":"In this paper, we present the modeling, simulation and signal processing of Doppler radar for heart beat and reparation sensing. Distance dependency of accuracy of heart and respiration signal from radar output is investigated and verified through simulation. The model is experimentally validated with commercially available motion detector DNO-341. The based band signal containing respiration and heartbeat signatures are low-pass filtered (0.7 Hz) for the respiration and band-pass filtered (0.9-2.5 Hz) for the heart signal. The estimated heart beat per minute and peak-peak interval is verified with result obtained from standard ECG measurement.","PeriodicalId":318875,"journal":{"name":"2015 International Conference on Signal Processing and Communication (ICSC)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Signal Processing and Communication (ICSC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSPCOM.2015.7150652","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

In this paper, we present the modeling, simulation and signal processing of Doppler radar for heart beat and reparation sensing. Distance dependency of accuracy of heart and respiration signal from radar output is investigated and verified through simulation. The model is experimentally validated with commercially available motion detector DNO-341. The based band signal containing respiration and heartbeat signatures are low-pass filtered (0.7 Hz) for the respiration and band-pass filtered (0.9-2.5 Hz) for the heart signal. The estimated heart beat per minute and peak-peak interval is verified with result obtained from standard ECG measurement.
用于心肺传感的微波多普勒雷达系统建模与信号处理
本文介绍了多普勒雷达的建模、仿真和信号处理。研究了雷达输出的心脏和呼吸信号的精度与距离的相关性,并通过仿真进行了验证。该模型用市售运动检测器DNO-341进行了实验验证。包含呼吸和心跳信号的基于频带信号对呼吸信号进行低通滤波(0.7 Hz),对心脏信号进行带通滤波(0.9-2.5 Hz)。估计的每分钟心跳数和峰峰间隔与标准心电图测量结果进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信