A Critical Study on the Protection Coordination System of a 2000kVA - LV Panel 5 of Student Dormitory in located at Al Khoud, Oman

Imadudin Faraj Al Hajri, Suresh Manic Kesavan, Abdulaziz Faraz Obaid Al-Hajri, N. S. Madhavaraja
{"title":"A Critical Study on the Protection Coordination System of a 2000kVA - LV Panel 5 of Student Dormitory in located at Al Khoud, Oman","authors":"Imadudin Faraj Al Hajri, Suresh Manic Kesavan, Abdulaziz Faraz Obaid Al-Hajri, N. S. Madhavaraja","doi":"10.1109/ICSCAN53069.2021.9526345","DOIUrl":null,"url":null,"abstract":"The heart of the power system is the protection coordination. It is important that an electrical fault must be cleared within a short period of time in order to ensure quality and reliable operation. This can only be achieved by properly coordinated protective equipment such as circuit breakers and/or relays. In this research study, the researcher focuses on the protection coordination system of a 2000kVA – Low Voltage (LV) Panel 5 of student dormitory in university area located at Al Khoud, Oman. Protective device will be critically reviewed if it is based on local and international standards like the Authority for Electricity Regulation – Oman Electrical Standards (AER-OES) and Institute of Electrical and Electronics Engineering (IEEE) or British Standard (BS). A single line diagram of the 2000kVA – LV Panel 5 of student dormitory was taken into account and studied. Symmetrical and unsymmetrical magnitude of fault currents were determined at different locations using per unit method which is essential in determining the minimum Kilo Ampere Interrupting Capacity (kAIC) rating of circuit breaker at different fault locations; a pre-requisite in studying the distribution system if its protective device were properly coordinated. The researcher will ensure its effective coordination base on the data obtained and will graphically present its time-current curve (TCC) using ABB software.","PeriodicalId":393569,"journal":{"name":"2021 International Conference on System, Computation, Automation and Networking (ICSCAN)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on System, Computation, Automation and Networking (ICSCAN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSCAN53069.2021.9526345","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The heart of the power system is the protection coordination. It is important that an electrical fault must be cleared within a short period of time in order to ensure quality and reliable operation. This can only be achieved by properly coordinated protective equipment such as circuit breakers and/or relays. In this research study, the researcher focuses on the protection coordination system of a 2000kVA – Low Voltage (LV) Panel 5 of student dormitory in university area located at Al Khoud, Oman. Protective device will be critically reviewed if it is based on local and international standards like the Authority for Electricity Regulation – Oman Electrical Standards (AER-OES) and Institute of Electrical and Electronics Engineering (IEEE) or British Standard (BS). A single line diagram of the 2000kVA – LV Panel 5 of student dormitory was taken into account and studied. Symmetrical and unsymmetrical magnitude of fault currents were determined at different locations using per unit method which is essential in determining the minimum Kilo Ampere Interrupting Capacity (kAIC) rating of circuit breaker at different fault locations; a pre-requisite in studying the distribution system if its protective device were properly coordinated. The researcher will ensure its effective coordination base on the data obtained and will graphically present its time-current curve (TCC) using ABB software.
阿曼Al Khoud学生宿舍2000kVA - LV面板5保护协调系统的关键研究
电力系统的核心是保护协调。为了保证质量和可靠运行,必须在短时间内清除电气故障。这只能通过适当协调的保护设备,如断路器和/或继电器来实现。在本研究中,研究者对位于阿曼Al Khoud大学区的学生宿舍2000kVA -低压(LV)面板5的保护协调系统进行了研究。如果保护装置是基于当地和国际标准,如电力监管局-阿曼电气标准(AER-OES)和电气与电子工程研究所(IEEE)或英国标准(BS),则将对其进行严格审查。考虑并研究了学生宿舍2000kVA - LV面板5的单线图。采用每单元法确定不同位置的对称和非对称故障电流大小,这是确定断路器在不同故障位置的最小千安培中断容量(kAIC)额定值所必需的;配电系统的保护装置协调得当是研究配电系统的先决条件。研究人员将根据所获得的数据确保其有效协调,并将使用ABB软件以图形方式呈现其时间-电流曲线(TCC)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信