Design and development of a microcontroller based system for the measurement of blood pressure

N. Latha, B. Rama Murthy, K. Madhav, Ch. V. V. Ramana, Willem Clarke, V. Siva Kumar
{"title":"Design and development of a microcontroller based system for the measurement of blood pressure","authors":"N. Latha, B. Rama Murthy, K. Madhav, Ch. V. V. Ramana, Willem Clarke, V. Siva Kumar","doi":"10.1109/ICONRAEECE.2011.6129771","DOIUrl":null,"url":null,"abstract":"In the present study, a microcontroller based system for the measurement of blood pressure is designed and developed. It is based on the oscillometric method. A microcontroller MCF51QE128 is used in the present study. Further, an LCD module to display the data of systolic and diastolic blood pressure and MR2A16A asynchronous magneto resistive RAM to store measured values of systolic diastolic pressure values are interfaced with the microcontroller, which reduces the hardware complexity. Software is developed in C language using IAR embedded work bench IDE for cold fire due to the inherent language flexibility, the extent of support and its potential for portability across a wide range of hardware. The instrument is tested and results are found to be satisfactory. The instrument is handheld, rugged, low cost, low energy consumption, wearable and cost effective compared to the other commercially available.","PeriodicalId":305797,"journal":{"name":"2011 INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENTS IN ELECTRICAL, ELECTRONICS AND CONTROL ENGINEERING","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENTS IN ELECTRICAL, ELECTRONICS AND CONTROL ENGINEERING","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICONRAEECE.2011.6129771","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

In the present study, a microcontroller based system for the measurement of blood pressure is designed and developed. It is based on the oscillometric method. A microcontroller MCF51QE128 is used in the present study. Further, an LCD module to display the data of systolic and diastolic blood pressure and MR2A16A asynchronous magneto resistive RAM to store measured values of systolic diastolic pressure values are interfaced with the microcontroller, which reduces the hardware complexity. Software is developed in C language using IAR embedded work bench IDE for cold fire due to the inherent language flexibility, the extent of support and its potential for portability across a wide range of hardware. The instrument is tested and results are found to be satisfactory. The instrument is handheld, rugged, low cost, low energy consumption, wearable and cost effective compared to the other commercially available.
基于单片机的血压测量系统的设计与开发
本文设计并开发了一种基于单片机的血压测量系统。它是基于振荡法的。本研究采用单片机MCF51QE128。此外,通过LCD模块显示收缩压和舒张压数据,并通过MR2A16A异步磁阻RAM存储收缩压和舒张压的测量值,降低了硬件复杂度。软件是用C语言开发的,使用IAR嵌入式工作平台IDE冷火,由于固有的语言灵活性,支持的范围和它在各种硬件上的可移植性的潜力。对仪器进行了测试,结果令人满意。与其他市售仪器相比,该仪器具有手持式、坚固耐用、低成本、低能耗、可穿戴和成本效益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信