Relation of Vibrating Line to Location of Fovea Palatinae in Local Population

Hamna Khawaja, Uzma Shahid, W. U. Khan, Hira Asghar, HM Owais Nasim, A. Farooq
{"title":"Relation of Vibrating Line to Location of Fovea Palatinae in Local Population","authors":"Hamna Khawaja, Uzma Shahid, W. U. Khan, Hira Asghar, HM Owais Nasim, A. Farooq","doi":"10.25301/jpda.312.81","DOIUrl":null,"url":null,"abstract":"OBJECTIVE: The objective of this study was to assess the location of foveae palatinae in relation to vibrating line for developing posterior palatal seal to enhance retention of maxillary complete dentures. Retention of a complete denture is the major factor to resist the forces of dislodgement along the path of insertion. In complete denture fabrication, fovea palatinae is the guideline for the posterior extension in the maxilla. Fovea palatinae mucous gland secretion helps in the retention by forming a thin layer within the maxillary complete denture. METHODOLOGY: The study was conducted in Sharif College of Dentistry in Lahore, Pakistan on a sample size of two hundred and fifty dentate, partially dentate and edentate patients with different age groups. Clinical examination of the maxilla was conducted for assessment of the vibrating line, whether it was at, anterior to or posterior to the fovea palatinae. The researcher used an indelible pencil to mark the ah line i.e vibrating line and its distance with fovea palatinae was measured. RESULTS: Results were concluded using SPSS Version 23. The fovea palatinae were mostly found to be located at 1.68 mm±1.11 anterior to the vibrating line. Thus, the dentists should assess this distance for the posterior extension of the maxillary denture. CONCLUSION: Fovea palatinae location in relation to vibrating line is an important landmark for posterior palatal seal in a complete denture. In the majority of cases, fovea palatinae were located 1.68 mm±1.11 anterior to the vibrating line. KEYWORDS: Foveae Palatinae, Vibrating line, Retention, Posterior palatal seal.","PeriodicalId":191918,"journal":{"name":"Journal of the Pakistan Dental Association","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Pakistan Dental Association","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25301/jpda.312.81","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

OBJECTIVE: The objective of this study was to assess the location of foveae palatinae in relation to vibrating line for developing posterior palatal seal to enhance retention of maxillary complete dentures. Retention of a complete denture is the major factor to resist the forces of dislodgement along the path of insertion. In complete denture fabrication, fovea palatinae is the guideline for the posterior extension in the maxilla. Fovea palatinae mucous gland secretion helps in the retention by forming a thin layer within the maxillary complete denture. METHODOLOGY: The study was conducted in Sharif College of Dentistry in Lahore, Pakistan on a sample size of two hundred and fifty dentate, partially dentate and edentate patients with different age groups. Clinical examination of the maxilla was conducted for assessment of the vibrating line, whether it was at, anterior to or posterior to the fovea palatinae. The researcher used an indelible pencil to mark the ah line i.e vibrating line and its distance with fovea palatinae was measured. RESULTS: Results were concluded using SPSS Version 23. The fovea palatinae were mostly found to be located at 1.68 mm±1.11 anterior to the vibrating line. Thus, the dentists should assess this distance for the posterior extension of the maxillary denture. CONCLUSION: Fovea palatinae location in relation to vibrating line is an important landmark for posterior palatal seal in a complete denture. In the majority of cases, fovea palatinae were located 1.68 mm±1.11 anterior to the vibrating line. KEYWORDS: Foveae Palatinae, Vibrating line, Retention, Posterior palatal seal.
振动线与局部人群腭中央窝位置的关系
目的:本研究的目的是评估腭中央凹与振动线的关系,以发展后腭密封,以增强上颌全口义齿的固位。全口义齿的固位是抵抗沿插入路径移位力的主要因素。在全口义齿制作中,腭中央凹是上颌后伸的导向。腭中央窝黏液腺分泌有助于在上颌全口义齿内形成薄层固位。方法:该研究在巴基斯坦拉合尔谢里夫牙科学院进行,样本量为250名不同年龄组的牙齿,部分牙齿和牙齿患者。对上颌进行临床检查,以评估振动线是否位于腭中央窝,前部或后部。研究人员用不可磨灭的铅笔标记出ah线即振动线,并测量其与腭中央凹的距离。结果:采用SPSS Version 23对结果进行统计分析。腭中央窝多位于振动线前1.68 mm±1.11处。因此,牙医应该评估这个距离为上颌义齿后伸。结论:腭中央窝与振动线的相对位置是全口义齿后腭封闭的重要标志。在大多数病例中,腭中央窝位于振动线前1.68 mm±1.11。关键词:腭中央窝,振动线,固位,后腭封闭。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信