J. Kawai, M. Ogishima, J. Shinagawa, S. Nakamura, G. Sawa
{"title":"Dynamism of interconnected channels in water treed polyethylene under a constant voltage","authors":"J. Kawai, M. Ogishima, J. Shinagawa, S. Nakamura, G. Sawa","doi":"10.1109/CEIDP.1999.807846","DOIUrl":null,"url":null,"abstract":"As the ac loss current containing higher order harmonic waves is able to be detected even in a non-penetrated water treed sample, the detection of the 3rd harmonic wave has a potential for the diagnosis of CV cables. The authors have presented a model where current density j through channels interconnecting micro-voids is assumed to depend on electric field E asj=(/spl sigma//sub 0//h)/spl middot/sinh (h/spl middot/E), where h is a parameter which characterizes the electric field dependence of j and /spl sigma//sub 0/ is the conductivity in low electric fields. Currents of the fundamental and 3rd harmonic waves estimated by Fourier analysis have been numerically calculated by solving a non-linear differential equation of the equivalent circuit based on the model. The numerical results give a good agreement with the changes of the observed magnitudes of fundamental and 3rd harmonic waves, I/sub 1/ and I/sub 3/ and their phase angles /spl theta//sub 1/ and /spl theta//sub 3/, respectively, for the application of a constant voltage. It has been concluded that the length of interconnected channels in the water treed region grows with time after the application of a constant voltage.","PeriodicalId":267509,"journal":{"name":"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1999.807846","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14
Abstract
As the ac loss current containing higher order harmonic waves is able to be detected even in a non-penetrated water treed sample, the detection of the 3rd harmonic wave has a potential for the diagnosis of CV cables. The authors have presented a model where current density j through channels interconnecting micro-voids is assumed to depend on electric field E asj=(/spl sigma//sub 0//h)/spl middot/sinh (h/spl middot/E), where h is a parameter which characterizes the electric field dependence of j and /spl sigma//sub 0/ is the conductivity in low electric fields. Currents of the fundamental and 3rd harmonic waves estimated by Fourier analysis have been numerically calculated by solving a non-linear differential equation of the equivalent circuit based on the model. The numerical results give a good agreement with the changes of the observed magnitudes of fundamental and 3rd harmonic waves, I/sub 1/ and I/sub 3/ and their phase angles /spl theta//sub 1/ and /spl theta//sub 3/, respectively, for the application of a constant voltage. It has been concluded that the length of interconnected channels in the water treed region grows with time after the application of a constant voltage.