{"title":"A highly sensitive microfluidic device for bacterial detection in blood serum","authors":"M. Al-Adhami, E. Tan, G. Rao, Y. Rostov","doi":"10.1109/HIC.2017.8227601","DOIUrl":null,"url":null,"abstract":"Highly sensitive device to detect bacteria in blood serum is presented. The device comprises of a microfluidic component and an electronic reader. The microfluidic cassette acts as an enclosed vial. It is filled with the sample after mixing with an indicator dye. Then, it is inserted into a kinetics fluorometer. The rate of the fluorescence increase is proportional to the number of viable cells in the sample. The fluorometer is portable. The device was tested with both lyophilized and fresh whole blood serums that were spiked with E.coli. Concentrations as low as 10 CFU/mL were detected. This paper discusses both the procedure to detect the bacteria as well as the results for different bacterial concentrations.","PeriodicalId":120815,"journal":{"name":"2017 IEEE Healthcare Innovations and Point of Care Technologies (HI-POCT)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE Healthcare Innovations and Point of Care Technologies (HI-POCT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HIC.2017.8227601","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Highly sensitive device to detect bacteria in blood serum is presented. The device comprises of a microfluidic component and an electronic reader. The microfluidic cassette acts as an enclosed vial. It is filled with the sample after mixing with an indicator dye. Then, it is inserted into a kinetics fluorometer. The rate of the fluorescence increase is proportional to the number of viable cells in the sample. The fluorometer is portable. The device was tested with both lyophilized and fresh whole blood serums that were spiked with E.coli. Concentrations as low as 10 CFU/mL were detected. This paper discusses both the procedure to detect the bacteria as well as the results for different bacterial concentrations.
一种用于血清细菌检测的高灵敏度微流控装置
介绍了一种高灵敏度的血清细菌检测装置。该装置包括微流控元件和电子阅读器。微流体盒作为一个封闭的小瓶。与指示染料混合后,将样品填满。然后,将其插入动力学荧光计中。荧光增加的速率与样品中活细胞的数量成正比。荧光计是便携式的。该装置在冻干和新鲜全血血清中进行了测试,全血血清中加入了大肠杆菌。浓度低至10 CFU/mL。本文讨论了细菌的检测过程以及不同细菌浓度下的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信