Temperature properties of scintillators for PET detectors: A comparative study

W. Wolszczak, M. Moszynski, T. Szczesniak, M. Grodzicka, K. Kacperski
{"title":"Temperature properties of scintillators for PET detectors: A comparative study","authors":"W. Wolszczak, M. Moszynski, T. Szczesniak, M. Grodzicka, K. Kacperski","doi":"10.1109/NSSMIC.2014.7430768","DOIUrl":null,"url":null,"abstract":"In the comparative measurements, done in the same experimental conditions, various samples of NaI:Tl, CsI:Na, BGO, GSO, LSO, LuAG:Pr, LaBr3 and GAGG scintillators were tested. The temperature dependence of the light output, energy resolution and decay time constants of the light pulses were measured over the temperature range of -30 to 50 °C. The XP2020 photomultiplier was used with two different dividers: one optimized for light output and energy resolution measurement and the other one for the decay time constant. In the study of the light output the number of photoelectrons per energy unit (phe/MeV) was measured using Bertolaccini method. The light pulse shape was taken using the anode signal recorded by a digital oscilloscope triggered by a single channel analyzer set on 662 keV energy.","PeriodicalId":144711,"journal":{"name":"2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2014.7430768","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

In the comparative measurements, done in the same experimental conditions, various samples of NaI:Tl, CsI:Na, BGO, GSO, LSO, LuAG:Pr, LaBr3 and GAGG scintillators were tested. The temperature dependence of the light output, energy resolution and decay time constants of the light pulses were measured over the temperature range of -30 to 50 °C. The XP2020 photomultiplier was used with two different dividers: one optimized for light output and energy resolution measurement and the other one for the decay time constant. In the study of the light output the number of photoelectrons per energy unit (phe/MeV) was measured using Bertolaccini method. The light pulse shape was taken using the anode signal recorded by a digital oscilloscope triggered by a single channel analyzer set on 662 keV energy.
PET探测器用闪烁体温度特性的比较研究
在相同的实验条件下,对不同样品的NaI:Tl、CsI:Na、BGO、GSO、LSO、LuAG:Pr、LaBr3和GAGG闪烁体进行了对比测量。在-30 ~ 50℃的温度范围内,测量了光输出、能量分辨率和光脉冲衰减时间常数的温度依赖性。XP2020光电倍增管采用两种不同的分压器:一种用于光输出和能量分辨率测量,另一种用于衰减时间常数。在光输出的研究中,采用Bertolaccini方法测量了每能量单位(phe/MeV)的光电子数。利用设置在662 keV能量的单通道分析仪触发的数字示波器记录的阳极信号获取光脉冲形状。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信