Simulation of Silicon Nanowire Bio-sensors

P. Nair, M. Alam
{"title":"Simulation of Silicon Nanowire Bio-sensors","authors":"P. Nair, M. Alam","doi":"10.1109/DRC.2006.305048","DOIUrl":null,"url":null,"abstract":"To summarize the results, we find that (a) the sensitivity of a NW-sensor depends on device parameters in unexpected ways, (b) sensitivity is greatly affected by the presence of water, and (c) for bio-molecule detection, for maximum sensitivity, the pH should be so chosen that the NW is in depletion. Our simulation results demonstrates, for the first time, that it is possible to interpret the conductance modulation of nano-bio sensors in terms of specific molecule conjugations and to systematically optimize sensor response as a function of sensor geometry and fluidic conditions.","PeriodicalId":259981,"journal":{"name":"2006 64th Device Research Conference","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 64th Device Research Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DRC.2006.305048","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

To summarize the results, we find that (a) the sensitivity of a NW-sensor depends on device parameters in unexpected ways, (b) sensitivity is greatly affected by the presence of water, and (c) for bio-molecule detection, for maximum sensitivity, the pH should be so chosen that the NW is in depletion. Our simulation results demonstrates, for the first time, that it is possible to interpret the conductance modulation of nano-bio sensors in terms of specific molecule conjugations and to systematically optimize sensor response as a function of sensor geometry and fluidic conditions.
硅纳米线生物传感器的仿真
总结结果,我们发现(a) NW传感器的灵敏度以意想不到的方式依赖于设备参数,(b)灵敏度受到水的存在的极大影响,以及(c)对于生物分子检测,为了获得最大灵敏度,pH值的选择应该使NW耗尽。我们的模拟结果首次证明,可以根据特定的分子偶联来解释纳米生物传感器的电导调制,并系统地优化传感器响应作为传感器几何形状和流体条件的函数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信