{"title":"Validation of partial discharge calibrators for small charge rates","authors":"R. Procházka, J. Hlavacek","doi":"10.1109/EPE58302.2023.10149257","DOIUrl":null,"url":null,"abstract":"Partial discharge measurement is one of the standard tools for diagnosing the state of high-voltage insulation systems. Before the measurement, it is necessary to calibrate the entire circuit using a calibrator that generates an accurate charge value. There are now emerging requirements to increase the verification accuracy of these calibrators for charge values less than a few pC. In this paper, a comparison is made between two possible calibration procedures, namely the numerical integration method and the procedure using special charge-sensitive amplifiers. The comparison is made based on uncertainty analysis and practical laboratory measurements. The results show that the use of charge-sensitive amplifiers brings a significant reduction of the calibration uncertainty in the small charge region.","PeriodicalId":210548,"journal":{"name":"2023 23rd International Scientific Conference on Electric Power Engineering (EPE)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 23rd International Scientific Conference on Electric Power Engineering (EPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE58302.2023.10149257","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Partial discharge measurement is one of the standard tools for diagnosing the state of high-voltage insulation systems. Before the measurement, it is necessary to calibrate the entire circuit using a calibrator that generates an accurate charge value. There are now emerging requirements to increase the verification accuracy of these calibrators for charge values less than a few pC. In this paper, a comparison is made between two possible calibration procedures, namely the numerical integration method and the procedure using special charge-sensitive amplifiers. The comparison is made based on uncertainty analysis and practical laboratory measurements. The results show that the use of charge-sensitive amplifiers brings a significant reduction of the calibration uncertainty in the small charge region.