{"title":"Automatic delineation of single-lead electrocardiograph fiducial points based on the hierarchical triple-extreme-points model","authors":"Xiaoshuang Shi, Yue Zhang","doi":"10.1109/ICCE-CHINA.2013.6780859","DOIUrl":null,"url":null,"abstract":"This paper introduces a novel single-lead electrocardiograph (ECG) automatic delineator based on the hierarchical triple-extreme-points model (HTM) and self-learning, featuring high robustness, low computational cost and mathematical simplicity. By applying HTM to obtaining the local morphological features of ECG signals, this method is capable of precisely detecting QRS complexes, P-wave and T-wave. In the experimental studies, this method was validated by several standard real-world ECG databases, including MIT-BIH arrhythmia, QT, European ST-T and TWA Challenge 2008 databases. For QRS detection, the average sensitivity value was 99.74% and the positive predictivity value was 99.80% for all databases. In the meantime, for P-wave and T-wave detection on QT, the sensitivity values were 99.49% and 99.81% respectively and the positive predictivity values were 98.82 and 99.80% respectively. As to delineation, the average maximum delineation error was no more than 4 ms and the standard deviation error was around 10ms for P-wave, QRS complex and T-wave.","PeriodicalId":293342,"journal":{"name":"2013 IEEE International Conference on Consumer Electronics - China","volume":"66 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Conference on Consumer Electronics - China","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCE-CHINA.2013.6780859","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper introduces a novel single-lead electrocardiograph (ECG) automatic delineator based on the hierarchical triple-extreme-points model (HTM) and self-learning, featuring high robustness, low computational cost and mathematical simplicity. By applying HTM to obtaining the local morphological features of ECG signals, this method is capable of precisely detecting QRS complexes, P-wave and T-wave. In the experimental studies, this method was validated by several standard real-world ECG databases, including MIT-BIH arrhythmia, QT, European ST-T and TWA Challenge 2008 databases. For QRS detection, the average sensitivity value was 99.74% and the positive predictivity value was 99.80% for all databases. In the meantime, for P-wave and T-wave detection on QT, the sensitivity values were 99.49% and 99.81% respectively and the positive predictivity values were 98.82 and 99.80% respectively. As to delineation, the average maximum delineation error was no more than 4 ms and the standard deviation error was around 10ms for P-wave, QRS complex and T-wave.