Ihsan A. Mkashaf, Kamel H. Al-Sowdani, Abdulla J. Y. Aldarwish
{"title":"Use of full automated microfluidic technique for determination of Zinc (II) in pharmaceutical preparations with 8-Hydroxyquinoline","authors":"Ihsan A. Mkashaf, Kamel H. Al-Sowdani, Abdulla J. Y. Aldarwish","doi":"10.56714/bjrs.48.2.2","DOIUrl":null,"url":null,"abstract":"The full automated microfluidic system has been designed for the determination of zinc (II) ion in pharmaceutical samples home-made. Two-channel microchips (30 μl×4 cm) was designed in this study. The proposed system was controlled by using Arduino UNO and Mega microcontrollers. The first type was utilized to control the homemade micro-peristaltic pump to withdraw samples and chemical reagents in the microchip and then to the spectrophotometer equipment with 7-microliter flow cell. The other one type is Mega, was used as a data-logger to manipulate and recording the results as peak height corresponding the concentration by using Microsoft Excel 2016 program. The linearity was ranged 1-7 µg/ml, the correlation coefficient (R2) was 0.9998. The relative standard deviation for ten measurements of Zn(II) ion 4 µg/ml was (0.982%), as well as the detection limit was 0.125 µg/ml. The dilution factor of this system was 1.07.","PeriodicalId":377834,"journal":{"name":"Basrah Researches Sciences","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Basrah Researches Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.56714/bjrs.48.2.2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The full automated microfluidic system has been designed for the determination of zinc (II) ion in pharmaceutical samples home-made. Two-channel microchips (30 μl×4 cm) was designed in this study. The proposed system was controlled by using Arduino UNO and Mega microcontrollers. The first type was utilized to control the homemade micro-peristaltic pump to withdraw samples and chemical reagents in the microchip and then to the spectrophotometer equipment with 7-microliter flow cell. The other one type is Mega, was used as a data-logger to manipulate and recording the results as peak height corresponding the concentration by using Microsoft Excel 2016 program. The linearity was ranged 1-7 µg/ml, the correlation coefficient (R2) was 0.9998. The relative standard deviation for ten measurements of Zn(II) ion 4 µg/ml was (0.982%), as well as the detection limit was 0.125 µg/ml. The dilution factor of this system was 1.07.