Designs synthesis of resonant fault current limiter for voltage sag mitigation and current limitation

C. Chang, P. Loh
{"title":"Designs synthesis of resonant fault current limiter for voltage sag mitigation and current limitation","authors":"C. Chang, P. Loh","doi":"10.1109/PESW.2000.847199","DOIUrl":null,"url":null,"abstract":"Recently, due to the influx of digital computers and other types of electronics controls, electric utilities are paying more attention to voltage sag mitigation. Solid-state fault current limiters (FCLs) have been proposed as a means for sag mitigation in the literature. However, not all FCL configurations are suitable for sag mitigation. This paper presents the shortcomings (transient complications) introduced by the thyristor-controlled resonant FCL proposed by G.G. Karady in the literature. In addition, two modified versions of the resonant FCL, with sag mitigation and fault current limiting capabilities, are proposed for use on distribution systems. Sensitivity analysis is then performed on the modified FCLs to determine the effects of component and network parameters on the current limiter performances.","PeriodicalId":286352,"journal":{"name":"2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"30","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESW.2000.847199","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 30

Abstract

Recently, due to the influx of digital computers and other types of electronics controls, electric utilities are paying more attention to voltage sag mitigation. Solid-state fault current limiters (FCLs) have been proposed as a means for sag mitigation in the literature. However, not all FCL configurations are suitable for sag mitigation. This paper presents the shortcomings (transient complications) introduced by the thyristor-controlled resonant FCL proposed by G.G. Karady in the literature. In addition, two modified versions of the resonant FCL, with sag mitigation and fault current limiting capabilities, are proposed for use on distribution systems. Sensitivity analysis is then performed on the modified FCLs to determine the effects of component and network parameters on the current limiter performances.
设计了一种用于电压暂降和限流的谐振式故障限流器
最近,由于数字计算机和其他类型的电子控制的涌入,电力公司越来越重视电压暂降的缓解。在文献中,固态故障电流限制器(FCLs)已被提出作为一种缓解凹陷的手段。然而,并不是所有的FCL配置都适合缓解凹陷。本文介绍了G.G. Karady在文献中提出的晶闸管控制谐振FCL的缺点(瞬态并发症)。此外,还提出了两种改进版本的谐振式FCL,它们具有抑制凹陷和限制故障电流的能力,可用于配电系统。然后对改进后的fcl进行灵敏度分析,以确定元件和网络参数对限流器性能的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信