Jing Fang, Hongxia Sun, Yin Liu, Bin Li, Sheng Lou
{"title":"On the Use of M00201 Peristaltic Pump in Infusion Configuration of Pharmacy Intravenous Admixture Services Based on the Hospital Information System","authors":"Jing Fang, Hongxia Sun, Yin Liu, Bin Li, Sheng Lou","doi":"10.1109/ICDSBA53075.2021.00050","DOIUrl":null,"url":null,"abstract":"Objective: This project is to explore the application value of M00201 peristaltic pump in the infusion configuration of pharmacy intravenous admixture services (PIVAS). Methods: In the PIVAS infusion configuration, the disposable sterile empty needle was used as the control group, and the peristaltic pump was used as the experimental group. Results: The average preparation time of Aidi Injection, Marsdenia Tenacissima Injection, Cervus and Cucumis Polypeptide Injection, Kangai Injection, Levofloxacin Injection, Imipenem and Cilastatin for Injection in the experimental group was 34.21s±, 42.62s±, 13.68s±, 21.82s±, 24.11s±, 21.01s±, which was significantly less than that in the control group (73.62s±, 73.81s±, 24.08s±, 35.02s±, 49.17s±, 27.73s±). Compare different configuration methods before and after using peristaltic pump for 6 kinds of drugs, and there was a significant difference in the time required to complete the infusion preparation (P<0.05). Conclusion: The application of the peristaltic pump in the infusion configuration is easy to operate and can shorten the configuration time, which can effectively improve the efficiency of the intravenous drug configuration, ensure the safety of the clinical medication and improve the quality of the pharmaceutical care. With the assistance of Hospital Information System (HIS), this experiment classifies and records the problems existing in the traditional infusion configuration. This system then summarizes, contrasts and analyzes the experimental data, putting forward and implementing improvement measures accordingly. And the value in using the device in infusion configuration can be discussed thereby.","PeriodicalId":154348,"journal":{"name":"2021 5th Annual International Conference on Data Science and Business Analytics (ICDSBA)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 5th Annual International Conference on Data Science and Business Analytics (ICDSBA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICDSBA53075.2021.00050","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: This project is to explore the application value of M00201 peristaltic pump in the infusion configuration of pharmacy intravenous admixture services (PIVAS). Methods: In the PIVAS infusion configuration, the disposable sterile empty needle was used as the control group, and the peristaltic pump was used as the experimental group. Results: The average preparation time of Aidi Injection, Marsdenia Tenacissima Injection, Cervus and Cucumis Polypeptide Injection, Kangai Injection, Levofloxacin Injection, Imipenem and Cilastatin for Injection in the experimental group was 34.21s±, 42.62s±, 13.68s±, 21.82s±, 24.11s±, 21.01s±, which was significantly less than that in the control group (73.62s±, 73.81s±, 24.08s±, 35.02s±, 49.17s±, 27.73s±). Compare different configuration methods before and after using peristaltic pump for 6 kinds of drugs, and there was a significant difference in the time required to complete the infusion preparation (P<0.05). Conclusion: The application of the peristaltic pump in the infusion configuration is easy to operate and can shorten the configuration time, which can effectively improve the efficiency of the intravenous drug configuration, ensure the safety of the clinical medication and improve the quality of the pharmaceutical care. With the assistance of Hospital Information System (HIS), this experiment classifies and records the problems existing in the traditional infusion configuration. This system then summarizes, contrasts and analyzes the experimental data, putting forward and implementing improvement measures accordingly. And the value in using the device in infusion configuration can be discussed thereby.