Development of optical sensor for determination of perchlorate ions

N. B. Messaoud, C. Dridi, M. N. Abbas
{"title":"Development of optical sensor for determination of perchlorate ions","authors":"N. B. Messaoud, C. Dridi, M. N. Abbas","doi":"10.1109/DTS55284.2022.9809846","DOIUrl":null,"url":null,"abstract":"An optical sensor for perchlorate anions (CIO<inf>4</inf>-) comprising a structure of Cobalt phthalocyanine derivative (Co(II)Pc-PAA) modified glass electrode has been developed. The immobilization of Co(II)Pc-PAA membrane was confirmed by contact angle measurements. The response was determined by the increase in the absorbance signal as a function of exposure to buffer solutions containing different concentrations of CIO<inf>4</inf>- anions. The optical sensor showed a linear response to CI04- from 10<sup>–10</sup>M to 10<sup>–2</sup> M, with a limit of detection of 4.81 Χ10<sup>−10</sup>M, one of the lowest achieved up until now. The proposed sensor has demonstrated a good specificity to CIO<inf>4</inf>- when compared to common interferents anions such as CI<sup>−</sup>and NO<inf>3</inf>-. To the best of our knowledge, this is the first optode system for the detection of CIO<inf>4</inf>-, which provides a promising sensor for the specific and sensitive determination of CIO<inf>4</inf>- in environmental water samples.","PeriodicalId":290904,"journal":{"name":"2022 IEEE International Conference on Design & Test of Integrated Micro & Nano-Systems (DTS)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Conference on Design & Test of Integrated Micro & Nano-Systems (DTS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DTS55284.2022.9809846","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

An optical sensor for perchlorate anions (CIO4-) comprising a structure of Cobalt phthalocyanine derivative (Co(II)Pc-PAA) modified glass electrode has been developed. The immobilization of Co(II)Pc-PAA membrane was confirmed by contact angle measurements. The response was determined by the increase in the absorbance signal as a function of exposure to buffer solutions containing different concentrations of CIO4- anions. The optical sensor showed a linear response to CI04- from 10–10M to 10–2 M, with a limit of detection of 4.81 Χ10−10M, one of the lowest achieved up until now. The proposed sensor has demonstrated a good specificity to CIO4- when compared to common interferents anions such as CIand NO3-. To the best of our knowledge, this is the first optode system for the detection of CIO4-, which provides a promising sensor for the specific and sensitive determination of CIO4- in environmental water samples.
高氯酸盐离子光学传感器的研制
研制了一种由酞菁钴衍生物(Co(II)Pc-PAA)修饰玻璃电极结构组成的高氯酸盐阴离子(CIO4-)光学传感器。通过接触角的测定证实了Co(II)Pc-PAA膜的固定化作用。这种响应是通过暴露于含有不同浓度的CIO4-阴离子的缓冲溶液中吸光度信号的增加来确定的。该光学传感器对CI04-在10-10M到10 - 2m范围内呈线性响应,检测限为4.81 Χ10−10M,是迄今为止实现的最低检测限之一。与常见的干扰阴离子(如CI -和NO3-)相比,该传感器对CIO4-具有良好的特异性。据我们所知,这是第一个用于检测CIO4-的光电系统,它为环境水样中CIO4-的特异性和敏感性测定提供了一个有前途的传感器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信