Selection of a Suitable Material by a Multi-Criteria Decision Aid Method (MCDM) for the Manufacture of the Buckets of a Micro Pelton Turbine

U. Emmanuel, H. Olivier, Hirwa Gloria, Nkubito Muhayeyezu Jean Olivier
{"title":"Selection of a Suitable Material by a Multi-Criteria Decision Aid Method (MCDM) for the Manufacture of the Buckets of a Micro Pelton Turbine","authors":"U. Emmanuel, H. Olivier, Hirwa Gloria, Nkubito Muhayeyezu Jean Olivier","doi":"10.54536/ajenr.v2i1.1219","DOIUrl":null,"url":null,"abstract":"This article aims to investigate the effect of inertia on the outlet temperature of an evacuated tube solar collector. The experiments were conducted during a 24h period in Minquin County (latitude 38034’N, Longitude 10303’E). An analysis was made to determine whether the evacuated tube solar collectors’ fluid thermal inertia impacts the water storage tank temperature. The results showed differences between the useful energy delivered to the water storage tank in the case with mass flow rate adjusted depending on the incident solar radiation for the entire two days in which experiments were conducted. Two days of cloud and sunshine were considered. An indirect optimal control technique refers to the impacts of the inertia of water on the outlet collector temperature, the on/off control of the pump, and the useful heat gain from the storage tank. During days with clear sky, the average solar radiation, mass flow rate, outlet, and tank temperature were 640.02W/m2, 0.06kg/s, 290C, and 44.240C, respectively. For cloudy day was 449W/m2, 0.02kg/s, 270C and 420C respectively. The control system is provided to run the heating circulating pump after rest for several minutes to facilitate the exhaust system, then continues to run for a cycle. The DTP,ON and DTP, OFF range from 30C to 100C and from 0.20C to 1.50C, respectively.","PeriodicalId":235456,"journal":{"name":"American Journal of Energy and Natural Resources","volume":"381 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Energy and Natural Resources","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54536/ajenr.v2i1.1219","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This article aims to investigate the effect of inertia on the outlet temperature of an evacuated tube solar collector. The experiments were conducted during a 24h period in Minquin County (latitude 38034’N, Longitude 10303’E). An analysis was made to determine whether the evacuated tube solar collectors’ fluid thermal inertia impacts the water storage tank temperature. The results showed differences between the useful energy delivered to the water storage tank in the case with mass flow rate adjusted depending on the incident solar radiation for the entire two days in which experiments were conducted. Two days of cloud and sunshine were considered. An indirect optimal control technique refers to the impacts of the inertia of water on the outlet collector temperature, the on/off control of the pump, and the useful heat gain from the storage tank. During days with clear sky, the average solar radiation, mass flow rate, outlet, and tank temperature were 640.02W/m2, 0.06kg/s, 290C, and 44.240C, respectively. For cloudy day was 449W/m2, 0.02kg/s, 270C and 420C respectively. The control system is provided to run the heating circulating pump after rest for several minutes to facilitate the exhaust system, then continues to run for a cycle. The DTP,ON and DTP, OFF range from 30C to 100C and from 0.20C to 1.50C, respectively.
用多准则辅助决策法(MCDM)选择微球式水轮机筒体的合适材料
本文旨在研究惯性对真空管太阳能集热器出口温度的影响。实验在明昆县(北纬38034′n,东经10303′e) 24小时内进行。分析了真空管太阳能集热器的流体热惯性对储水箱温度的影响。结果显示,在进行实验的整个两天内,根据入射太阳辐射调整质量流量的情况下,输送到储水箱的有用能量之间存在差异。他们考虑了两天的阴天和晴天。间接最优控制技术是指水的惯性对出口集热器温度、泵的开/关控制和储罐的有用热增益的影响。晴空时,平均太阳辐射为640.02W/m2,质量流量为0.06kg/s,出口温度为290C,水箱温度为44.240C。阴天为449W/m2, 0.02kg/s, 270℃,420℃。控制系统用于加热循环泵在休息几分钟后运行,以方便排气系统,然后继续运行一个循环。DTP,ON和DTP, OFF的范围分别为30℃至100℃和0.20℃至1.5℃。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信