Design of low power IR-UWB transmitter for healthcare monitoring applications

I. Barraj, H. Trabelsi, M. Masmoudi, Adbdelkader Bouzid, Ali Djebou
{"title":"Design of low power IR-UWB transmitter for healthcare monitoring applications","authors":"I. Barraj, H. Trabelsi, M. Masmoudi, Adbdelkader Bouzid, Ali Djebou","doi":"10.1109/ICCMA.2013.6506154","DOIUrl":null,"url":null,"abstract":"There is an increasing need to develop low power medical devices for healthcare monitoring applications. Recently advancement in microelectronics, micro electro mechanical systems (MEMS), telecommunications and micro biomedical sensors have enabled both development and design of such devices. Different solutions have been developed such as wireless sensor networks (WSN), intelligent habitat systems and so on. In this paper, we focus on the actimery concept. The aim is the design of RF transmitter architecture to ensure the real time data transmission. The proposed architecture is based on the IEEE 802.15.4a standard and it operates in the mandatory channel 3 of the low band. The transmitter is expected to working at a data rate of 0.850 Kbps and using BPSK modulation. The simulated TX has peak amplitude of 325mV, transmitted power of − 13.05dBm and a noise figure of 9.2dB.","PeriodicalId":187834,"journal":{"name":"2013 International Conference on Computer Medical Applications (ICCMA)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Conference on Computer Medical Applications (ICCMA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCMA.2013.6506154","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

There is an increasing need to develop low power medical devices for healthcare monitoring applications. Recently advancement in microelectronics, micro electro mechanical systems (MEMS), telecommunications and micro biomedical sensors have enabled both development and design of such devices. Different solutions have been developed such as wireless sensor networks (WSN), intelligent habitat systems and so on. In this paper, we focus on the actimery concept. The aim is the design of RF transmitter architecture to ensure the real time data transmission. The proposed architecture is based on the IEEE 802.15.4a standard and it operates in the mandatory channel 3 of the low band. The transmitter is expected to working at a data rate of 0.850 Kbps and using BPSK modulation. The simulated TX has peak amplitude of 325mV, transmitted power of − 13.05dBm and a noise figure of 9.2dB.
用于医疗监测应用的低功率IR-UWB发射机设计
为医疗监控应用开发低功耗医疗设备的需求越来越大。最近在微电子、微机电系统(MEMS)、电信和微型生物医学传感器方面的进步使这种设备的开发和设计成为可能。不同的解决方案已经被开发出来,如无线传感器网络(WSN)、智能栖息地系统等。在本文中,我们关注的是活动概念。目的是设计射频发射机的结构,以保证数据的实时传输。该架构基于IEEE 802.15.a标准,工作在低频段的强制信道3上。发射机预计将以0.850 Kbps的数据速率工作,并使用BPSK调制。仿真的TX峰值幅值为325mV,发射功率为- 13.05dBm,噪声系数为9.2dB。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信