{"title":"Evaluation of a VNA-based material characterization kit at frequencies from 0.75 THz to 1.1 THz","authors":"A. Khalid, D. Cumming, R. Clarke, Chong Li, N. Ridler","doi":"10.1109/UCMMT.2016.7873952","DOIUrl":null,"url":null,"abstract":"This paper describes an initial assessment of a commercially available THz material characterization kit (MCK). The assessment is based on the measurement of several material samples. The MCK comprises two conical waveguide horn transitions and two sections of low-loss corrugated waveguide. A gap between the two corrugated waveguides allows the material samples to be inserted into the system during measurement. The MCK is attached to a THz Vector Network Analyzer (VNA), which measures S-parameters, in the frequency domain, of a material under test (MUT). A computer-based algorithm employing an iterative calculation derives values for material parameters (e.g. permittivity) from the measured S-parameters of the MUT. A MCK has been evaluated over the frequency range 0.75 THz to 1.1 THz, to assess the plausibility of results that can be obtained using such a technique. Two VNAs utilizing frequency extender heads were used for the investigation, with measurements being made with reference to a range of different calibration techniques and different calibration standards. Whilst some of the results obtained look reasonable, a significant proportion of the results were either difficult to interpret or showed inexplicable (i.e. non-physical) behavior. This indicates that much work is still needed before this technique can be used routinely for the measurement of material parameters at these very high frequencies.","PeriodicalId":380332,"journal":{"name":"2016 IEEE 9th UK-Europe-China Workshop on Millimetre Waves and Terahertz Technologies (UCMMT)","volume":"52 56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 9th UK-Europe-China Workshop on Millimetre Waves and Terahertz Technologies (UCMMT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UCMMT.2016.7873952","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

This paper describes an initial assessment of a commercially available THz material characterization kit (MCK). The assessment is based on the measurement of several material samples. The MCK comprises two conical waveguide horn transitions and two sections of low-loss corrugated waveguide. A gap between the two corrugated waveguides allows the material samples to be inserted into the system during measurement. The MCK is attached to a THz Vector Network Analyzer (VNA), which measures S-parameters, in the frequency domain, of a material under test (MUT). A computer-based algorithm employing an iterative calculation derives values for material parameters (e.g. permittivity) from the measured S-parameters of the MUT. A MCK has been evaluated over the frequency range 0.75 THz to 1.1 THz, to assess the plausibility of results that can be obtained using such a technique. Two VNAs utilizing frequency extender heads were used for the investigation, with measurements being made with reference to a range of different calibration techniques and different calibration standards. Whilst some of the results obtained look reasonable, a significant proportion of the results were either difficult to interpret or showed inexplicable (i.e. non-physical) behavior. This indicates that much work is still needed before this technique can be used routinely for the measurement of material parameters at these very high frequencies.
基于vna的材料表征试剂盒在0.75太赫兹到1.1太赫兹频率范围内的评估
本文描述了对市售太赫兹材料表征试剂盒(MCK)的初步评估。评估是基于对几个材料样品的测量。MCK包括两个锥形波导喇叭转换和两段低损耗波纹波导。两个波纹波导之间的间隙允许在测量期间将材料样品插入系统。MCK与太赫兹矢量网络分析仪(VNA)相连,该分析仪在频域测量被测材料(MUT)的s参数。采用迭代计算的基于计算机的算法从MUT的测量s参数中导出材料参数(例如介电常数)的值。在0.75太赫兹到1.1太赫兹的频率范围内对MCK进行了评估,以评估使用这种技术可以获得的结果的合理性。调查使用了两个使用频率扩展头的vna,并参考了一系列不同的校准技术和不同的校准标准进行测量。虽然获得的一些结果看起来是合理的,但很大一部分结果要么难以解释,要么表现出无法解释的(即非物理)行为。这表明,在这种技术可以在这些非常高的频率下用于常规测量材料参数之前,还有很多工作要做。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书