D. Hansen, D. Ristau, T. Spaeth, W. Radasky, K.S. Smith, J. Gilbert
{"title":"Analysis of the measured field structure in a GTEM 1750","authors":"D. Hansen, D. Ristau, T. Spaeth, W. Radasky, K.S. Smith, J. Gilbert","doi":"10.1109/ISEMC.1994.385667","DOIUrl":null,"url":null,"abstract":"An experimental field mapping (x, y, z components) of a GTEM 1750 has been performed in important parts and locations of this asymmetrical waveguide. The measurement results of deviations from the perfect TEM wave reveal some non TEM components as a function of exciting frequency and measurement location. A review of the present state of theoretical and experimental research with respect to immunity is given. An attempt is made to simulate a generic GTEM 500 section by using a 3-D finite difference time domain code. A comparison with measured data is presented, including the analysis of fundamental problems in the presently used standardized field sensor instrumentation.<<ETX>>","PeriodicalId":154914,"journal":{"name":"Proceedings of IEEE Symposium on Electromagnetic Compatibility","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of IEEE Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.1994.385667","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16
Abstract
An experimental field mapping (x, y, z components) of a GTEM 1750 has been performed in important parts and locations of this asymmetrical waveguide. The measurement results of deviations from the perfect TEM wave reveal some non TEM components as a function of exciting frequency and measurement location. A review of the present state of theoretical and experimental research with respect to immunity is given. An attempt is made to simulate a generic GTEM 500 section by using a 3-D finite difference time domain code. A comparison with measured data is presented, including the analysis of fundamental problems in the presently used standardized field sensor instrumentation.<>
在该非对称波导的重要部位和位置进行了GTEM 1750的x, y, z分量的实验场映射。与瞬变电磁波的偏差测量结果显示,一些非瞬变电磁波分量随激发频率和测量位置的变化而变化。对免疫的理论和实验研究现状进行了综述。尝试用三维时域有限差分码对通用GTEM 500剖面进行模拟。并与实测数据进行了比较,分析了目前使用的标准化现场传感器仪器存在的基本问题。