Electromagnetic radiated field measurements for partial discharge diagnostic

G. Ala, R. Candela, P. Romano, R. Schifani, F. Viola
{"title":"Electromagnetic radiated field measurements for partial discharge diagnostic","authors":"G. Ala, R. Candela, P. Romano, R. Schifani, F. Viola","doi":"10.1109/CEIDP.2003.1254935","DOIUrl":null,"url":null,"abstract":"Recently, improvements have been made in the diagnostic of electrical insulation systems by means of electric Partial Discharge (PD) standard measurements through a stochastic approach in the treatment of the acquired data: in this way, the identification of the defects as well as the separation of multiple defects simultaneously active, have been successfully performed. However, the standard PD measurement process can be affected by the well-known parasitic effects due to conducted noise whose spectrum can have characteristics similar to those of the measured signal. Moreover, the classic PD measurement system have to be suitable assembled on the Device Under Test (DUT) so determining a complex erection on site operations, which can force the temporary outage of the same DUT and the related equipment. In the aim of overcoming the previous limitations of the classic PD measurement system, in this paper a novel approach for the characterization of the defects in a dielectric material is proposed. It is based on the remote measurement of the ElectroMagnetic (EM) transient field radiated from PD. In order to validate the approach, the standard CIGRE I test cell is used. Different test measurements with different spatial sensors location enable to obtain the PD diagnostic. A comparison with standard electric current-voltage PD measurements has been carried out with a good agreement in terms of diagnostic results.","PeriodicalId":306575,"journal":{"name":"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2003.1254935","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Recently, improvements have been made in the diagnostic of electrical insulation systems by means of electric Partial Discharge (PD) standard measurements through a stochastic approach in the treatment of the acquired data: in this way, the identification of the defects as well as the separation of multiple defects simultaneously active, have been successfully performed. However, the standard PD measurement process can be affected by the well-known parasitic effects due to conducted noise whose spectrum can have characteristics similar to those of the measured signal. Moreover, the classic PD measurement system have to be suitable assembled on the Device Under Test (DUT) so determining a complex erection on site operations, which can force the temporary outage of the same DUT and the related equipment. In the aim of overcoming the previous limitations of the classic PD measurement system, in this paper a novel approach for the characterization of the defects in a dielectric material is proposed. It is based on the remote measurement of the ElectroMagnetic (EM) transient field radiated from PD. In order to validate the approach, the standard CIGRE I test cell is used. Different test measurements with different spatial sensors location enable to obtain the PD diagnostic. A comparison with standard electric current-voltage PD measurements has been carried out with a good agreement in terms of diagnostic results.
局部放电诊断用电磁辐射场测量
最近,通过随机方法处理所获得的数据,采用局部放电(PD)标准测量方法对电气绝缘系统的诊断进行了改进:通过这种方法,可以成功地识别缺陷并分离同时活动的多个缺陷。然而,标准PD测量过程会受到众所周知的寄生效应的影响,寄生效应是由传导噪声引起的,其频谱可能具有与被测信号相似的特征。此外,经典的PD测量系统必须合适地组装在被测设备(DUT)上,以便在现场操作中确定复杂的安装,这可能会迫使同一DUT和相关设备暂时中断。为了克服传统PD测量系统的局限性,本文提出了一种表征介电材料缺陷的新方法。它是基于对PD辐射的电磁瞬态场的远程测量。为了验证该方法,使用了标准CIGRE I测试单元。不同的测试测量与不同的空间传感器位置,可以获得PD诊断。与标准的电流-电压PD测量进行了比较,在诊断结果方面有很好的一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信