Silicon micromachined gas chromatography system

E. Kolesar, R. Reston
{"title":"Silicon micromachined gas chromatography system","authors":"E. Kolesar, R. Reston","doi":"10.1109/ICISS.1997.630252","DOIUrl":null,"url":null,"abstract":"A miniature gas chromatography (GC) system has been designed and fabricated using silicon micromachining and integrated circuit (IC) processing techniques. The silicon micromachined gas chromatography system (SMGCS) is composed of a miniature sample injector that incorporates a 10 /spl mu/l sample loop; a 0.9-m long, rectangular-shaped (300 /spl mu/m width and 10 /spl mu/m height) capillary column coated with a 0.2-/spl mu/m thick copper phthalocyanine (CuPc) stationary-phase; and a dual-detector scheme based upon a CuPc-coated chemiresistor and a commercially available, 125-/spl mu/m diameter thermal conductivity detector (TCD) bead. Silicon micromachining was employed to fabricate the interface between the sample injector and the GC column, the column itself, and the dual-detector cavity. A novel IC thin-film processing technique was developed to sublime the CuPc stationary-phase coating on the column walls that were micromachined in the host silicon wafer substrate and Pyrex cover plate, which were then electrostatically bonded together. The SMGCS can separate binary gas mixtures composed of parts per-million (ppm) concentrations of ammonia (NH/sub 3/) and nitrogen dioxide (NO/sub 2/) when isothermally operated (55-80/spl deg/C). With a helium carrier gas and nitrogen diluent, a 10 /spl mu/l sample volume containing ammonia and nitrogen dioxide injected at 40 psi (2.8/spl times/10/sup 5/ Pa) can be separated in less than 30 minutes.","PeriodicalId":357602,"journal":{"name":"1997 Proceedings Second Annual IEEE International Conference on Innovative Systems in Silicon","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1997 Proceedings Second Annual IEEE International Conference on Innovative Systems in Silicon","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICISS.1997.630252","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

Abstract

A miniature gas chromatography (GC) system has been designed and fabricated using silicon micromachining and integrated circuit (IC) processing techniques. The silicon micromachined gas chromatography system (SMGCS) is composed of a miniature sample injector that incorporates a 10 /spl mu/l sample loop; a 0.9-m long, rectangular-shaped (300 /spl mu/m width and 10 /spl mu/m height) capillary column coated with a 0.2-/spl mu/m thick copper phthalocyanine (CuPc) stationary-phase; and a dual-detector scheme based upon a CuPc-coated chemiresistor and a commercially available, 125-/spl mu/m diameter thermal conductivity detector (TCD) bead. Silicon micromachining was employed to fabricate the interface between the sample injector and the GC column, the column itself, and the dual-detector cavity. A novel IC thin-film processing technique was developed to sublime the CuPc stationary-phase coating on the column walls that were micromachined in the host silicon wafer substrate and Pyrex cover plate, which were then electrostatically bonded together. The SMGCS can separate binary gas mixtures composed of parts per-million (ppm) concentrations of ammonia (NH/sub 3/) and nitrogen dioxide (NO/sub 2/) when isothermally operated (55-80/spl deg/C). With a helium carrier gas and nitrogen diluent, a 10 /spl mu/l sample volume containing ammonia and nitrogen dioxide injected at 40 psi (2.8/spl times/10/sup 5/ Pa) can be separated in less than 30 minutes.
硅微机械气相色谱系统
采用硅微加工和集成电路加工技术,设计并制造了微型气相色谱(GC)系统。硅微机气相色谱系统(SMGCS)由一个微型样品进样器组成,该进样器包含一个10 /spl μ l /l样品环;长0.9 m的矩形毛细管柱(宽300 /spl亩米,高10 /spl亩米),涂有厚0.2 /spl亩米的酞菁铜固定相;以及基于纸杯涂层化学电阻器和市售125-/spl mu/m直径热导率检测器(TCD)珠的双探测器方案。样品进样器与气相色谱柱、气相色谱柱和双检测器腔之间的界面采用硅微机械加工。提出了一种新颖的集成电路薄膜加工技术,将CuPc固定相涂层涂覆在微机械加工的硅片衬底和Pyrex盖板上的柱壁上,然后静电粘合在一起。SMGCS在等温操作(55-80/spl℃)时可以分离由百万分之一(ppm)浓度的氨(nh3 /)和二氧化氮(NO/ sub2 /)组成的二元气体混合物。使用氦气载气和氮气稀释剂,在40 psi (2.8/spl次/10/sup 5/ Pa)下注入含有氨和二氧化氮的10/ spl mu/l样品体积可以在不到30分钟内分离。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信