Open ended coaxial line for electrical characterization of human blood

F. Jaspard, M. Nadi
{"title":"Open ended coaxial line for electrical characterization of human blood","authors":"F. Jaspard, M. Nadi","doi":"10.1109/IEMBS.2001.1017463","DOIUrl":null,"url":null,"abstract":"An open-ended coaxial line was used for measurement of the complex permittivity of human blood. In dielectric characterization, modelling of the probe is a fundamental step, which permits the relationship between the complex electric admittance and the complex permittivity to be obtained. The electrical equivalent circuit model was investigated and the performances for blood measurement were estimated. In this paper we present the evaluation of a probe configuration as regards the frequency and the permittivity range measurement. The proposed model permits us to obtained result on fresh heparined human blood close to the literature value.","PeriodicalId":386546,"journal":{"name":"2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":"134 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.2001.1017463","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

An open-ended coaxial line was used for measurement of the complex permittivity of human blood. In dielectric characterization, modelling of the probe is a fundamental step, which permits the relationship between the complex electric admittance and the complex permittivity to be obtained. The electrical equivalent circuit model was investigated and the performances for blood measurement were estimated. In this paper we present the evaluation of a probe configuration as regards the frequency and the permittivity range measurement. The proposed model permits us to obtained result on fresh heparined human blood close to the literature value.
人体血液电学特性的开口同轴线
采用开放式同轴线测量人体血液的复介电常数。在介质表征中,探针的建模是一个基本步骤,它允许得到复导纳和复介电常数之间的关系。研究了等效电路模型,并对其在血液测量中的性能进行了估计。在本文中,我们提出了一种探头结构在频率和介电常数范围测量方面的评价。所提出的模型使我们得到的新鲜人肝素血的结果接近文献值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信