Application of a new electrometric approach to study interaction between biological molecules

N. Starodub, Igor P. Goraychuk, V. M. Starodub, V. V. Il’chenko, G. V. Kuznetsov
{"title":"Application of a new electrometric approach to study interaction between biological molecules","authors":"N. Starodub, Igor P. Goraychuk, V. M. Starodub, V. V. Il’chenko, G. V. Kuznetsov","doi":"10.1117/12.382319","DOIUrl":null,"url":null,"abstract":"In the paper the results about changes of the current- voltage characteristics of the surface-barrier structures (SBS) after the deposition of myoglobin and its specific monoclonal antibodies are presented. It was shown that the SBS structures with ultra-thin films or with ultra-thin layer of the porous silicon are sensitive to the presence of the protein or its specific immune complex on their surfaces. The response of the system depended on the conditions of the specific complex formation. The characteristic optimum of the thickness of Ni film or the layer of the porous silicon was revealed when the changes of the I-V characteristics had a maximum level.","PeriodicalId":318748,"journal":{"name":"Design, Test, Integration, and Packaging of MEMS/MOEMS","volume":"271 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Design, Test, Integration, and Packaging of MEMS/MOEMS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.382319","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In the paper the results about changes of the current- voltage characteristics of the surface-barrier structures (SBS) after the deposition of myoglobin and its specific monoclonal antibodies are presented. It was shown that the SBS structures with ultra-thin films or with ultra-thin layer of the porous silicon are sensitive to the presence of the protein or its specific immune complex on their surfaces. The response of the system depended on the conditions of the specific complex formation. The characteristic optimum of the thickness of Ni film or the layer of the porous silicon was revealed when the changes of the I-V characteristics had a maximum level.
一种新的电测量方法在生物分子间相互作用研究中的应用
本文报道了肌红蛋白及其特异性单克隆抗体沉积后表面屏障结构(SBS)电流电压特性的变化。结果表明,具有超薄薄膜或具有超薄多孔硅层的SBS结构对其表面存在的蛋白质或其特异性免疫复合物敏感。系统的响应取决于特定复杂地层的条件。当I-V特性变化达到最大水平时,呈现出Ni膜厚度或多孔硅层厚度的最优特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信