Screen Printed Silver/Carbon Composite Strain Gauge on a TPU Platform for Wearable Applications

A. K. Bose, D. Maddipatla, X. Zhang, M. Panahi, S. Masihi, B. B. Narakathu, B. Bazuin, M. Atashbar
{"title":"Screen Printed Silver/Carbon Composite Strain Gauge on a TPU Platform for Wearable Applications","authors":"A. K. Bose, D. Maddipatla, X. Zhang, M. Panahi, S. Masihi, B. B. Narakathu, B. Bazuin, M. Atashbar","doi":"10.1109/FLEPS49123.2020.9239547","DOIUrl":null,"url":null,"abstract":"A printed strain gauge based on silver/carbon composite was successfully fabricated and characterized for strain monitoring applications. The silver-carbon (Ag/C) composite ink was prepared by blending 81% wt. of silver with 19% wt. of carbon ink. The strain gauge was fabricated by screen printing Ag/C composite ink on a flexible and stretchable thermoplastic polyurethane (TPU) substrate in a meandering pattern to achieve a desired resistance of $\\sim 350 \\Omega$. The capability of the printed strain gauge to detect varying strains ranging from 0% to 5% was investigated. It was observed that the strain gauge had a linear response till 2.5% strain. At 2.5% of tensile strain a relative resistive change of 7.8% and a gauge factor of 3.1 was observed. However, as the strain increased beyond 2.5% the strain gauge had a non-linear response. It was observed that at a tensile strain of 5%, the strain gauge had a maximum relative resistive change of 285.6% resulting in 57.2 gauge factor. The results demonstrate that a screen-printed Ag/C composite ink-based strain gauge with on a TPU substrate can be utilized for strain monitoring. The electromechanical response of the fabricated strain gauge as a function of resistance is investigated and presented in this paper.","PeriodicalId":101496,"journal":{"name":"2020 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FLEPS49123.2020.9239547","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

A printed strain gauge based on silver/carbon composite was successfully fabricated and characterized for strain monitoring applications. The silver-carbon (Ag/C) composite ink was prepared by blending 81% wt. of silver with 19% wt. of carbon ink. The strain gauge was fabricated by screen printing Ag/C composite ink on a flexible and stretchable thermoplastic polyurethane (TPU) substrate in a meandering pattern to achieve a desired resistance of $\sim 350 \Omega$. The capability of the printed strain gauge to detect varying strains ranging from 0% to 5% was investigated. It was observed that the strain gauge had a linear response till 2.5% strain. At 2.5% of tensile strain a relative resistive change of 7.8% and a gauge factor of 3.1 was observed. However, as the strain increased beyond 2.5% the strain gauge had a non-linear response. It was observed that at a tensile strain of 5%, the strain gauge had a maximum relative resistive change of 285.6% resulting in 57.2 gauge factor. The results demonstrate that a screen-printed Ag/C composite ink-based strain gauge with on a TPU substrate can be utilized for strain monitoring. The electromechanical response of the fabricated strain gauge as a function of resistance is investigated and presented in this paper.
用于可穿戴应用的TPU平台的丝网印刷银/碳复合应变计
成功制备了一种基于银/碳复合材料的印刷应变片,并对其进行了表征,用于应变监测。采用81掺杂法制备银碳(Ag/C)复合油墨% wt. of silver with 19% wt. of carbon ink. The strain gauge was fabricated by screen printing Ag/C composite ink on a flexible and stretchable thermoplastic polyurethane (TPU) substrate in a meandering pattern to achieve a desired resistance of $\sim 350 \Omega$. The capability of the printed strain gauge to detect varying strains ranging from 0% to 5% was investigated. It was observed that the strain gauge had a linear response till 2.5% strain. At 2.5% of tensile strain a relative resistive change of 7.8% and a gauge factor of 3.1 was observed. However, as the strain increased beyond 2.5% the strain gauge had a non-linear response. It was observed that at a tensile strain of 5%, the strain gauge had a maximum relative resistive change of 285.6% resulting in 57.2 gauge factor. The results demonstrate that a screen-printed Ag/C composite ink-based strain gauge with on a TPU substrate can be utilized for strain monitoring. The electromechanical response of the fabricated strain gauge as a function of resistance is investigated and presented in this paper.
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信