{"title":"Gamma radiation effects on bipolar transistors a comparison of surface mount and standard packages","authors":"S.L. Pater, R. Sharp","doi":"10.1109/RADECS.1995.509772","DOIUrl":null,"url":null,"abstract":"Gamma radiation total dose effects on unbiased bipolar transistors in both surface mount and standard packages have been assessed. Total doses of up to 1 MGy have been covered at a dose rate of 12.6 kGy[H/sub 2/O]/hr, using a cobalt-60 source. No significant differences in the radiation effects between the two package styles were observed.","PeriodicalId":310087,"journal":{"name":"Proceedings of the Third European Conference on Radiation and its Effects on Components and Systems","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Third European Conference on Radiation and its Effects on Components and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RADECS.1995.509772","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
Gamma radiation total dose effects on unbiased bipolar transistors in both surface mount and standard packages have been assessed. Total doses of up to 1 MGy have been covered at a dose rate of 12.6 kGy[H/sub 2/O]/hr, using a cobalt-60 source. No significant differences in the radiation effects between the two package styles were observed.