{"title":"A Software Tool for Setting Upstream Active Power Protection in a Meshed Distribution Network","authors":"V. Krcal, D. Topolanek, Viktor Jurák, J. Orságová","doi":"10.1109/EPE58302.2023.10149288","DOIUrl":null,"url":null,"abstract":"The paper deals with a problem of upstream active power flows in MV/LV meshed distribution networks in case of a fault at MV side. The concept of upstream active power protection (UAPP) is presented as an alternative to directional overcurrent relays. The paper contribution is focused on a software tool for calculation of the UAPP setting. Presented method is based on short-circuit faults simulations using numerical model of the network in order to define threshold values respecting limiting conditions at each MV/LV transformer. The paper discusses one-stage/two-stage and individual/global variant of setting the UAPP units. The algorithm principle is demonstrated using extensive MV/LV meshed network model with graphical illustration of derived thresholds.","PeriodicalId":210548,"journal":{"name":"2023 23rd International Scientific Conference on Electric Power Engineering (EPE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 23rd International Scientific Conference on Electric Power Engineering (EPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE58302.2023.10149288","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The paper deals with a problem of upstream active power flows in MV/LV meshed distribution networks in case of a fault at MV side. The concept of upstream active power protection (UAPP) is presented as an alternative to directional overcurrent relays. The paper contribution is focused on a software tool for calculation of the UAPP setting. Presented method is based on short-circuit faults simulations using numerical model of the network in order to define threshold values respecting limiting conditions at each MV/LV transformer. The paper discusses one-stage/two-stage and individual/global variant of setting the UAPP units. The algorithm principle is demonstrated using extensive MV/LV meshed network model with graphical illustration of derived thresholds.