{"title":"Turbogenerator Rotor Interturn Fault Detection Using the Leakage Field Analysis - Case Study","authors":"A. Miletic, D. Turk, J. Polak","doi":"10.1109/DEMPED.2007.4393135","DOIUrl":null,"url":null,"abstract":"In this case 270,5 MVA turbogenerator was tested. The goal of the test was to diagnose the quality of the generator by using the on-line leakage field analysis during the normal machine operation. The leakage field was measured using the specially designed search coil. The search coil voltage was analyzed in time domain and in frequency domain using FFT.","PeriodicalId":185737,"journal":{"name":"2007 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives","volume":"81 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEMPED.2007.4393135","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
In this case 270,5 MVA turbogenerator was tested. The goal of the test was to diagnose the quality of the generator by using the on-line leakage field analysis during the normal machine operation. The leakage field was measured using the specially designed search coil. The search coil voltage was analyzed in time domain and in frequency domain using FFT.