Evaluating dynamic maximum power point tracking with variable solar irradiance

M. Huque, S. Coley, T. Key
{"title":"Evaluating dynamic maximum power point tracking with variable solar irradiance","authors":"M. Huque, S. Coley, T. Key","doi":"10.1109/PVSC-VOL2.2013.7179250","DOIUrl":null,"url":null,"abstract":"Photovoltaic (PV) plant performance, among many factors, depends on inverter tracking of the maximum power point and its energy conversion efficiency. For a given PV array, under certain environmental conditions, the energy yield depends on the inverter's dynamic response for maximum power point tracking (MPPT) with highly variable array output. This paper describes the theoretical irradiance test profile proposed in a European Norm Standard (EN 50530:2010) for inverter Dynamic MPPT efficiency evaluation. Example test results from two inverters are included. This paper also reports some discrepancy in the standard test profile by comparing the required test environment with high resolution measured solar irradiance ramp rate data for a South-East and a Western part of USA.","PeriodicalId":413736,"journal":{"name":"2013 IEEE 39th Photovoltaic Specialists Conference (PVSC) PART 2","volume":"229 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE 39th Photovoltaic Specialists Conference (PVSC) PART 2","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PVSC-VOL2.2013.7179250","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Photovoltaic (PV) plant performance, among many factors, depends on inverter tracking of the maximum power point and its energy conversion efficiency. For a given PV array, under certain environmental conditions, the energy yield depends on the inverter's dynamic response for maximum power point tracking (MPPT) with highly variable array output. This paper describes the theoretical irradiance test profile proposed in a European Norm Standard (EN 50530:2010) for inverter Dynamic MPPT efficiency evaluation. Example test results from two inverters are included. This paper also reports some discrepancy in the standard test profile by comparing the required test environment with high resolution measured solar irradiance ramp rate data for a South-East and a Western part of USA.
用可变太阳辐照度评价动态最大功率点跟踪
光伏电站的性能在诸多因素中取决于逆变器对最大功率点的跟踪及其能量转换效率。对于给定的光伏阵列,在一定的环境条件下,其发电量取决于逆变器对阵列输出高度可变的最大功率点跟踪(MPPT)的动态响应。本文描述了欧洲规范标准(EN 50530:2010)中提出的逆变器动态MPPT效率评估的理论辐照度测试剖面。包括两个逆变器的示例测试结果。本文还通过对美国东南部和西部地区高分辨率太阳辐照度斜坡率测量数据进行比较,报告了标准测试剖面的一些差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信