{"title":"Multivariable control of sextuple tank system with non-minimum phase dynamics","authors":"D. Copot, A. Maxim, R. Keyser, C. Ionescu","doi":"10.1109/AQTR.2016.7501361","DOIUrl":null,"url":null,"abstract":"In this paper we present experimental results of a multivariable linear predictive control strategy applied to a coupled, non-minimum phase dynamics system of six coupled water tanks with 3 controlled water levels (cm) and 3 manipulated pump outputs (V). The setup can be considered as three interacting sub-systems, with coupled dynamics due to the specific water flow directions. The experimental results indicate that the proposed strategy is robust to significant modelling errors, while maintaining good performance.","PeriodicalId":110627,"journal":{"name":"2016 IEEE International Conference on Automation, Quality and Testing, Robotics (AQTR)","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Conference on Automation, Quality and Testing, Robotics (AQTR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AQTR.2016.7501361","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
In this paper we present experimental results of a multivariable linear predictive control strategy applied to a coupled, non-minimum phase dynamics system of six coupled water tanks with 3 controlled water levels (cm) and 3 manipulated pump outputs (V). The setup can be considered as three interacting sub-systems, with coupled dynamics due to the specific water flow directions. The experimental results indicate that the proposed strategy is robust to significant modelling errors, while maintaining good performance.