Reproducibility of CISPR 25 alse test method

C. Carobbi, Danilo Izzo
{"title":"Reproducibility of CISPR 25 alse test method","authors":"C. Carobbi, Danilo Izzo","doi":"10.1109/emcsi.2018.8495374","DOIUrl":null,"url":null,"abstract":"The reproducibility of the Absorber Lined Shielded Enclosure (ALSE) radiated emission test method, defined in the standard CISPR 25, is evaluated through an interlaboratory comparison (ILC). The ILC started on September 2016 and concluded on February 2017. Nineteen data sets have been received. The investigated frequency range is from 1 MHz to 1000 MHz. The most critical (worst reproducibility) frequency range is the one from 10 MHz to 50 MHz where the robust (outlier-resistant) standard deviation of the measured values is comprised between 5 dB and 8 dB. In the frequency range from 50 MHz to 1000 MHz the robust standard deviation is comprised between 2 dB and 3 dB. The main causes of non-reproducibility are identified and test setup adjustments aimed at improving the reproducibility are proposed.","PeriodicalId":426924,"journal":{"name":"2017 IEEE International Symposium on Electromagnetic Compatibility & Signal/Power Integrity (EMCSI)","volume":"43 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE International Symposium on Electromagnetic Compatibility & Signal/Power Integrity (EMCSI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/emcsi.2018.8495374","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

The reproducibility of the Absorber Lined Shielded Enclosure (ALSE) radiated emission test method, defined in the standard CISPR 25, is evaluated through an interlaboratory comparison (ILC). The ILC started on September 2016 and concluded on February 2017. Nineteen data sets have been received. The investigated frequency range is from 1 MHz to 1000 MHz. The most critical (worst reproducibility) frequency range is the one from 10 MHz to 50 MHz where the robust (outlier-resistant) standard deviation of the measured values is comprised between 5 dB and 8 dB. In the frequency range from 50 MHz to 1000 MHz the robust standard deviation is comprised between 2 dB and 3 dB. The main causes of non-reproducibility are identified and test setup adjustments aimed at improving the reproducibility are proposed.
CISPR 25假体试验方法的重复性
标准CISPR 25中定义的吸收器衬里屏蔽罩(ALSE)辐射发射测试方法的再现性通过实验室间比较(ILC)进行评估。ILC于2016年9月启动,2017年2月结束。已收到19组数据。所研究的频率范围是从1mhz到1000mhz。最关键(再现性最差)的频率范围是从10mhz到50mhz,其中测量值的鲁棒(抗离群值)标准偏差在5db到8db之间。在50mhz到1000mhz的频率范围内,鲁棒标准偏差由2db到3db组成。指出了导致试验结果不可重复性的主要原因,并提出了提高试验结果可重复性的调整方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信