Design and implementation of a robust fault detection mechanism for EHV lines

S. Hareesh, P. Raja, M. P. Selvan
{"title":"Design and implementation of a robust fault detection mechanism for EHV lines","authors":"S. Hareesh, P. Raja, M. P. Selvan","doi":"10.1109/ICPEICES.2016.7853200","DOIUrl":null,"url":null,"abstract":"This paper presents a robust fault detection mechanism in EHV lines by using Wavelet transform and FFT analysis. db6 is chosen as mother wavelet since it is best one to analyze the transients during faults and load switching. The simulated results are validated with the experimental results. For fault detection 2nd harmonic spectral component and energy difference of the consecutive windows are used as deciding parameters for fault detection. The algorithm is robust such that it won't issue trip signal for the load changes. But in the case of any fault in the system (LG fault in this paper) both second harmonic and difference of energy of consecutive windows exceeds threshold value and issues trip signal. The status of the transmission network is monitored in a mobile application developed for android.","PeriodicalId":305942,"journal":{"name":"2016 IEEE 1st International Conference on Power Electronics, Intelligent Control and Energy Systems (ICPEICES)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 1st International Conference on Power Electronics, Intelligent Control and Energy Systems (ICPEICES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPEICES.2016.7853200","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper presents a robust fault detection mechanism in EHV lines by using Wavelet transform and FFT analysis. db6 is chosen as mother wavelet since it is best one to analyze the transients during faults and load switching. The simulated results are validated with the experimental results. For fault detection 2nd harmonic spectral component and energy difference of the consecutive windows are used as deciding parameters for fault detection. The algorithm is robust such that it won't issue trip signal for the load changes. But in the case of any fault in the system (LG fault in this paper) both second harmonic and difference of energy of consecutive windows exceeds threshold value and issues trip signal. The status of the transmission network is monitored in a mobile application developed for android.
超高压线路鲁棒故障检测机制的设计与实现
本文提出了一种基于小波变换和FFT分析的超高压线路鲁棒故障检测机制。选择Db6作为母小波,因为它是分析故障和负荷切换过程中暂态的最佳小波。仿真结果与实验结果相吻合。在故障检测中,采用连续窗口的二次谐波谱分量和能量差作为故障检测的决定参数。该算法具有鲁棒性,不会因负载变化而发出脱扣信号。但在系统发生故障时(本文为LG故障),连续窗口的二次谐波和能量差均超过阈值,发出跳闸信号。在为android开发的移动应用程序中监控传输网络的状态。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信