Measured Impedance by Distance Relay in Presence of Resistive Fault Current Limiter

S. Jamali, H. Shateri
{"title":"Measured Impedance by Distance Relay in Presence of Resistive Fault Current Limiter","authors":"S. Jamali, H. Shateri","doi":"10.1109/ICPST.2008.4745268","DOIUrl":null,"url":null,"abstract":"Distance relays are widely in use as main and back-up protective devices for transmission lines. Their operation is based on impedance measurement at the relaying point, which can be affected by several factors. Continued demand for electricity energy leads to increase in the short circuit levels along the network, which itself causes new problems. One of the proposed solutions for this problem is the utilization of fault current limiter (FCL), which imposes further changes on the measured impedance at the relaying point. This paper presents the effects of resistive superconductor FCL, on the measured impedance at the relaying point. In addition to its limitation degree, its installation point also affects the measured impedance. The variation of the ideal tripping characteristic due to presence of FCL for different installation points would be investigated.","PeriodicalId":107016,"journal":{"name":"2008 Joint International Conference on Power System Technology and IEEE Power India Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Joint International Conference on Power System Technology and IEEE Power India Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPST.2008.4745268","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Distance relays are widely in use as main and back-up protective devices for transmission lines. Their operation is based on impedance measurement at the relaying point, which can be affected by several factors. Continued demand for electricity energy leads to increase in the short circuit levels along the network, which itself causes new problems. One of the proposed solutions for this problem is the utilization of fault current limiter (FCL), which imposes further changes on the measured impedance at the relaying point. This paper presents the effects of resistive superconductor FCL, on the measured impedance at the relaying point. In addition to its limitation degree, its installation point also affects the measured impedance. The variation of the ideal tripping characteristic due to presence of FCL for different installation points would be investigated.
有阻性故障限流器的距离继电器测量阻抗
距离继电器作为输电线路的主保护装置和后备保护装置被广泛使用。它们的工作是基于继电点的阻抗测量,这可能受到几个因素的影响。对电能的持续需求导致电网沿线短路水平的增加,这本身就造成了新的问题。针对这个问题提出的解决方案之一是使用故障限流器(FCL),它对继电点的测量阻抗施加进一步的变化。本文介绍了电阻性超导体FCL对继电点测量阻抗的影响。除了它的限制程度外,它的安装位置也会影响被测阻抗。研究了在不同的安装点上,由于FCL的存在,理想脱扣特性的变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信