{"title":"High frequency behavior of AC machine: application of turn insulation aging diagnostic","authors":"F. Perisse, P. Werynski, D. Roger","doi":"10.1109/ELINSL.2006.1665379","DOIUrl":null,"url":null,"abstract":"The stator insulation breakdown is a major cause of AC machine failures. Ground insulation defaults are easily detected by classical systems based on the leakage current measurements, however the turn to turn insulation degradations are more difficult to detect. For large machines, on-line methods, based on partial discharge detection and analysis, give good results but they cannot be used for low-voltage machines fed by adjustable speed drives (ASD). This paper presents a new monitoring system able to detect slight variations of high frequency resonances in the winding of a working machine fed by an industrial inverter. The new system works in association with statistical data on the accelerated aging of the magnet wire","PeriodicalId":427638,"journal":{"name":"Conference Record of the 2006 IEEE International Symposium on Electrical Insulation","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2006 IEEE International Symposium on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2006.1665379","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

The stator insulation breakdown is a major cause of AC machine failures. Ground insulation defaults are easily detected by classical systems based on the leakage current measurements, however the turn to turn insulation degradations are more difficult to detect. For large machines, on-line methods, based on partial discharge detection and analysis, give good results but they cannot be used for low-voltage machines fed by adjustable speed drives (ASD). This paper presents a new monitoring system able to detect slight variations of high frequency resonances in the winding of a working machine fed by an industrial inverter. The new system works in association with statistical data on the accelerated aging of the magnet wire
交流电机高频特性:匝绝缘老化诊断的应用
定子绝缘击穿是交流电机故障的主要原因。基于泄漏电流测量的传统系统很容易检测到接地绝缘的默认值,但匝间绝缘的退化则很难检测到。对于大型机器,基于局部放电检测和分析的在线方法给出了良好的结果,但它们不能用于由调速驱动器(ASD)馈电的低压机器。本文提出了一种新的监测系统,该系统能够检测由工业逆变器供电的工作机器绕组中高频谐振的微小变化。新系统与磁线加速老化的统计数据相结合
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信