{"title":"Analysis of Current Resonances due to Winding Parasitic Capacitances in Medium-Voltage Medium-Frequency Transformers","authors":"R. Jimenez, G. Oggier, D. P. Fernandez, J. Balda","doi":"10.1109/APEC43599.2022.9773427","DOIUrl":null,"url":null,"abstract":"This paper presents the analysis of the current resonances on medium-voltage, medium-frequency transformers due to the parasitic capacitances of the windings. Converter performance is affected by these high-frequency current resonances; therefore, the winding arrangement of high-voltage high-turns ratio transformers must be carefully considered during the building process. Three different windings arrangements are built for a 5-kV-to-400-V, 10-kHz transformer for a high-power dual-active-bridge (DAB) converter. Open-circuit and short-circuit impedance response of the three windings are compared. Experimental results include open-circuit test on each of the three different winding arrangements and a 10 kW load test to illustrate the effect of the parasitic capacitances.","PeriodicalId":127006,"journal":{"name":"2022 IEEE Applied Power Electronics Conference and Exposition (APEC)","volume":"105 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Applied Power Electronics Conference and Exposition (APEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC43599.2022.9773427","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
This paper presents the analysis of the current resonances on medium-voltage, medium-frequency transformers due to the parasitic capacitances of the windings. Converter performance is affected by these high-frequency current resonances; therefore, the winding arrangement of high-voltage high-turns ratio transformers must be carefully considered during the building process. Three different windings arrangements are built for a 5-kV-to-400-V, 10-kHz transformer for a high-power dual-active-bridge (DAB) converter. Open-circuit and short-circuit impedance response of the three windings are compared. Experimental results include open-circuit test on each of the three different winding arrangements and a 10 kW load test to illustrate the effect of the parasitic capacitances.