Dynamic phasors in modeling of UPFC under unbalanced conditions

P. Stefanov, A. Stanković
{"title":"Dynamic phasors in modeling of UPFC under unbalanced conditions","authors":"P. Stefanov, A. Stanković","doi":"10.1109/ICPST.2000.900116","DOIUrl":null,"url":null,"abstract":"The paper describes an analytical model for unbalanced operation of the unified power flow controller (UPFC). This nonlinear, time-invariant model is expressed in terms of dynamic symmetric components, and it is validated on a benchmark power system example taken from the literature. The model is evaluated via simulations in unbalanced operation and during unbalanced (one phase to ground) faults. The model achieves an accuracy comparable to detailed time-domain models, in addition to a reduction in simulation time.","PeriodicalId":330989,"journal":{"name":"PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPST.2000.900116","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

The paper describes an analytical model for unbalanced operation of the unified power flow controller (UPFC). This nonlinear, time-invariant model is expressed in terms of dynamic symmetric components, and it is validated on a benchmark power system example taken from the literature. The model is evaluated via simulations in unbalanced operation and during unbalanced (one phase to ground) faults. The model achieves an accuracy comparable to detailed time-domain models, in addition to a reduction in simulation time.
不平衡条件下UPFC建模中的动态相量
本文建立了统一潮流控制器(UPFC)不平衡运行的分析模型。该非线性定常模型用动态对称分量表示,并在参考文献的基准电力系统实例上进行了验证。通过不平衡运行和不平衡(单相接地)故障的仿真,对该模型进行了评估。除了减少仿真时间外,该模型还实现了与详细时域模型相当的精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信