{"title":"Proton radiation test of DC/DC converter with high voltage output","authors":"S. Scherrer, W. Hajdas, U. Grossner, N. Schlumpf","doi":"10.1109/RADECS.2008.5782686","DOIUrl":null,"url":null,"abstract":"Radiation hardness of the COTS high voltage DC-DC converter was tested up to 90 krad(Si) using proton beams. Total dose effects with subsequent annealing were determined. Dependence on operating conditions and dose rate was observed. Mainly responsible parts were identified and functional failure of the device was attributed to the input current increase driven by power MOSFET.","PeriodicalId":173369,"journal":{"name":"2008 European Conference on Radiation and Its Effects on Components and Systems","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 European Conference on Radiation and Its Effects on Components and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RADECS.2008.5782686","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Radiation hardness of the COTS high voltage DC-DC converter was tested up to 90 krad(Si) using proton beams. Total dose effects with subsequent annealing were determined. Dependence on operating conditions and dose rate was observed. Mainly responsible parts were identified and functional failure of the device was attributed to the input current increase driven by power MOSFET.