A. Timmermeyer, H. Wojtczyk, W. Tenner, G. Bringout, M. Gruttner, M. Graeser, T. Sattel, A. Halkola, T. Buzug
{"title":"Super-resolution approaches for resolution enhancement in magnetic particle imaging","authors":"A. Timmermeyer, H. Wojtczyk, W. Tenner, G. Bringout, M. Gruttner, M. Graeser, T. Sattel, A. Halkola, T. Buzug","doi":"10.1109/IWMPI.2013.6528360","DOIUrl":null,"url":null,"abstract":"Given a definition of spatial resolution that considers two objects as distinguished if the minimum value of the gap is less than 50% of the value at the object position [7], both approaches achieved an improvement of the spatial resolution in the 1D simulation study as visualized in Fig. 1 and 2. If the spatial resolution is considered as the minimum width of two distinguished lines, the first approach using spatially shifted images achieved a spatial resolution of 1.7 mm and the second approach using different sampling points achieved a resolution of 2.6 mm. This is an improvement in comparison to the used low resolution images with a spatial resolution of 2 mm (first approach) and 2.9 mm (second approach).","PeriodicalId":267566,"journal":{"name":"2013 International Workshop on Magnetic Particle Imaging (IWMPI)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-03-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Workshop on Magnetic Particle Imaging (IWMPI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IWMPI.2013.6528360","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Given a definition of spatial resolution that considers two objects as distinguished if the minimum value of the gap is less than 50% of the value at the object position [7], both approaches achieved an improvement of the spatial resolution in the 1D simulation study as visualized in Fig. 1 and 2. If the spatial resolution is considered as the minimum width of two distinguished lines, the first approach using spatially shifted images achieved a spatial resolution of 1.7 mm and the second approach using different sampling points achieved a resolution of 2.6 mm. This is an improvement in comparison to the used low resolution images with a spatial resolution of 2 mm (first approach) and 2.9 mm (second approach).