Corona between point plane electrodes in air at atmospheric pressure

G. Gurumurthy
{"title":"Corona between point plane electrodes in air at atmospheric pressure","authors":"G. Gurumurthy","doi":"10.1109/CEIDP.2003.1254854","DOIUrl":null,"url":null,"abstract":"Several theoretical investigations have been reported in literature on electric field nonuniformity between point plane electrodes. In the present investigations experiments have been performed to determine corona onset voltages in air at atmospheric pressure between point plane electrodes for DC voltage applications of both polarities. The diameter of hemispherical tip of point electrodes used in experiments varied from 1.2 mm to 3.0 mm and gap distances varied from 20 mm to 50 mm (approximately). For these electrode arrangements, calculated variation of electrical field non uniformity factor was from 18 to 48. The measured corona inception voltages were found to increase with increase in diameter of point electrodes and also with increase in gap distance between electrodes. The calculated maximum stresses at tip of point electrode at corona inception are in approximate range of 70kv/cm to 135 kv/cm. The maximum stress, which appears for tip diameter of 1.2 mm for point electrode, does not significantly influence the field variation in these gaps as to disturb Townsend mechanism of ionization growth.","PeriodicalId":306575,"journal":{"name":"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2003.1254854","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Several theoretical investigations have been reported in literature on electric field nonuniformity between point plane electrodes. In the present investigations experiments have been performed to determine corona onset voltages in air at atmospheric pressure between point plane electrodes for DC voltage applications of both polarities. The diameter of hemispherical tip of point electrodes used in experiments varied from 1.2 mm to 3.0 mm and gap distances varied from 20 mm to 50 mm (approximately). For these electrode arrangements, calculated variation of electrical field non uniformity factor was from 18 to 48. The measured corona inception voltages were found to increase with increase in diameter of point electrodes and also with increase in gap distance between electrodes. The calculated maximum stresses at tip of point electrode at corona inception are in approximate range of 70kv/cm to 135 kv/cm. The maximum stress, which appears for tip diameter of 1.2 mm for point electrode, does not significantly influence the field variation in these gaps as to disturb Townsend mechanism of ionization growth.
大气压下空气中点平面电极之间的电晕
关于点平面电极间电场不均匀性的理论研究已有文献报道。在目前的研究中,已经进行了实验,以确定大气压力下两个极性直流电压应用的点平面电极之间的电晕起始电压。实验中使用的点电极的半球形尖端直径从1.2 mm到3.0 mm不等,间隙距离从20 mm到50 mm不等(约)。对于这些电极布置,计算得到电场不均匀系数的变化范围为18 ~ 48。电晕起始电压随点电极直径的增大和电极间隙距离的增大而增大。计算得到的电晕起始点电极尖端最大应力约为70kv/cm ~ 135kv /cm。点电极尖端直径为1.2 mm时出现的最大应力对这些间隙中的电场变化没有显著影响,从而干扰了汤森德电离生长机制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信