Wastewater Purification Technology by Two-Stage Treatment in Electrical Device of a Compact Local Installation

L. Chelyadyn, V. Kostyshyn, V. Chelyadyn, T. Romanyshyn, V. Vasechko
{"title":"Wastewater Purification Technology by Two-Stage Treatment in Electrical Device of a Compact Local Installation","authors":"L. Chelyadyn, V. Kostyshyn, V. Chelyadyn, T. Romanyshyn, V. Vasechko","doi":"10.15587/1729-4061.2020.206815","DOIUrl":null,"url":null,"abstract":"Wastewater generated at industrial and communal facilities is treated within the limits of permissible values established by law. The drains of transport and tourism infrastructure in most cases are cleared with local treatment facilities. For wastewater purification, the biological method is most often used, which is implemented on complex and bulky wastewater purification plants located in large areas. It is proposed to carry out wastewater purification from small objects locally using physical and electrochemical technology with compact equipment. A design of a device for treating wastewater with cylindrical electrodes located coaxially with the device casing has been developed. It is shown that at the first stage of municipal wastewater purification in a laboratory setup with the appropriate parameters (plane tilt angle in a thin-layer sedimentation tank=45° and voltage on the 1st electric device with a soluble anode=12 V), the purification degree from weighted to 95 is ensured, 8 %. The purification of municipal wastewater in the second stage of purification (the 2nd electric device with an inert anode at 10 V and filtering through the clinoptilolite zeolite layer) increases the purification degree from suspended to 96.1 %. Wastewater purification of a car wash in the first electric device in front of a thin-layer sedimentation tank and in the 2nd electric device with an inert anode at a voltage of 10 V and filtering through a layer of clinoptilolite zeolite increases the degree of their purification from oil products to 95.6 %. The technology with the participation of developed electrical appliances leads to an increase in the degree of wastewater purification in terms of COD to 97.0 %. which allows to reduce the pollution discharge into the environment at the level of 50–70 %.","PeriodicalId":308822,"journal":{"name":"Water Sustainability eJournal","volume":"71 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water Sustainability eJournal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15587/1729-4061.2020.206815","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Wastewater generated at industrial and communal facilities is treated within the limits of permissible values established by law. The drains of transport and tourism infrastructure in most cases are cleared with local treatment facilities. For wastewater purification, the biological method is most often used, which is implemented on complex and bulky wastewater purification plants located in large areas. It is proposed to carry out wastewater purification from small objects locally using physical and electrochemical technology with compact equipment. A design of a device for treating wastewater with cylindrical electrodes located coaxially with the device casing has been developed. It is shown that at the first stage of municipal wastewater purification in a laboratory setup with the appropriate parameters (plane tilt angle in a thin-layer sedimentation tank=45° and voltage on the 1st electric device with a soluble anode=12 V), the purification degree from weighted to 95 is ensured, 8 %. The purification of municipal wastewater in the second stage of purification (the 2nd electric device with an inert anode at 10 V and filtering through the clinoptilolite zeolite layer) increases the purification degree from suspended to 96.1 %. Wastewater purification of a car wash in the first electric device in front of a thin-layer sedimentation tank and in the 2nd electric device with an inert anode at a voltage of 10 V and filtering through a layer of clinoptilolite zeolite increases the degree of their purification from oil products to 95.6 %. The technology with the participation of developed electrical appliances leads to an increase in the degree of wastewater purification in terms of COD to 97.0 %. which allows to reduce the pollution discharge into the environment at the level of 50–70 %.
小型装置电气装置两级处理污水净化技术
工业和公共设施产生的废水在法律规定的容许值范围内进行处理。在大多数情况下,运输和旅游基础设施的排水沟是由当地的处理设施清除的。对于废水的净化,最常用的是生物法,它是在大面积的复杂和庞大的废水净化厂中实施的。建议采用物理和电化学技术,在小型设备上进行局部小物体废水净化。设计了一种与装置外壳同轴的圆柱形电极处理废水的装置。结果表明,在实验室装置中,在适当的参数(薄层沉淀池平面倾角为45°,第一电气装置电压为12 V,可溶阳极)下,城市污水净化第一阶段,净化度从加权到95,保证了8%。二级净化(第二级电装置采用10 V惰性阳极,经斜沸石沸石层过滤)对城市污水的净化,使净化程度由悬浮提高到96.1%。第一电动装置在薄层沉淀池前对洗车废水进行净化,第二电动装置在电压为10 V的惰性阳极下通过一层斜沸石沸石过滤,使其对油品的净化程度提高到95.6%。该技术在先进电器的参与下,使废水的COD净化程度提高到97.0%。这可以减少对环境的污染排放在50 - 70%的水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信