Voltage sags: their impact on the utility and industrial customers

T. Davis, G. E. Beam, C. Melhorn
{"title":"Voltage sags: their impact on the utility and industrial customers","authors":"T. Davis, G. E. Beam, C. Melhorn","doi":"10.1109/ICPS.1996.533938","DOIUrl":null,"url":null,"abstract":"This paper describes the impact of voltage sags on the utility and industrial customers. Several utility measures are presented to minimize the customer's exposure to voltage sags. However, these measures cannot completely eliminate the impact of voltage sags on sensitive equipment. A case study is presented in this paper that includes measurement results that were used to characterize the voltage sags experienced on the utility system and in the industrial facility, simulation results that were used to develop \"area of vulnerability curves\" for the industrial facility, mitigation equipment that was employed to improve the sensitive equipment's ride through capability, and the lessons learned from the systems approach analysis.","PeriodicalId":122944,"journal":{"name":"Proceedings of 1996 IAS Industrial and Commercial Power Systems Technical Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-05-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"130","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1996 IAS Industrial and Commercial Power Systems Technical Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPS.1996.533938","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 130

Abstract

This paper describes the impact of voltage sags on the utility and industrial customers. Several utility measures are presented to minimize the customer's exposure to voltage sags. However, these measures cannot completely eliminate the impact of voltage sags on sensitive equipment. A case study is presented in this paper that includes measurement results that were used to characterize the voltage sags experienced on the utility system and in the industrial facility, simulation results that were used to develop "area of vulnerability curves" for the industrial facility, mitigation equipment that was employed to improve the sensitive equipment's ride through capability, and the lessons learned from the systems approach analysis.
电压跌落:它们对公用事业和工业客户的影响
本文介绍了电压跌落对公用事业和工业用户的影响。提出了几种实用措施,以尽量减少客户暴露于电压跌落。然而,这些措施并不能完全消除电压跌落对敏感设备的影响。本文介绍了一个案例研究,其中包括用于描述公用事业系统和工业设施中经历的电压跌落特征的测量结果、用于为工业设施制定“脆弱区域曲线”的模拟结果、用于提高敏感设备穿越能力的缓解设备以及从系统方法分析中吸取的经验教训。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信