Comparative analysis of low dose-rate, accelerated, and standard cobalt-60 radiation response data for a low-dropout voltage regulator and a voltage reference
W. Abare, F. Brueggeman, R. Pease, J. Krieg, M. Simons
{"title":"Comparative analysis of low dose-rate, accelerated, and standard cobalt-60 radiation response data for a low-dropout voltage regulator and a voltage reference","authors":"W. Abare, F. Brueggeman, R. Pease, J. Krieg, M. Simons","doi":"10.1109/REDW.2002.1045550","DOIUrl":null,"url":null,"abstract":"This paper presents the results of cobalt-60 response measurements made on a low dropout voltage regulator and a shunt reference for three different radiation test conditions: low dose rate, accelerated (elevated temperature irradiation) and standard (50-300 rad(SiO/sub 2/)/s). The accelerated test is shown to correlate well with the low dose rate failure of the reference but not for the failure of the regulator.","PeriodicalId":135340,"journal":{"name":"IEEE Radiation Effects Data Workshop","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Radiation Effects Data Workshop","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/REDW.2002.1045550","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18
Abstract
This paper presents the results of cobalt-60 response measurements made on a low dropout voltage regulator and a shunt reference for three different radiation test conditions: low dose rate, accelerated (elevated temperature irradiation) and standard (50-300 rad(SiO/sub 2/)/s). The accelerated test is shown to correlate well with the low dose rate failure of the reference but not for the failure of the regulator.